6 Specifications
6.1 Absolute Maximum Ratings(1)(2)(3)
over operating free-air temperature range (unless otherwise noted)
VCC (V+ - V-)
IOUT
Common Mode Input Voltage
Maximum Junction Temperature
Soldering Information
Infrared or Convection (20 sec)
Wave Soldering (10 sec)
MIN
MAX
UNIT
±6.75
V
120 (4)
mA
±VCC
V
+150
°C
235
°C
260
°C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but specific performance is not ensured. For ensured specifications, see the Electrical
Characteristics tables.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(3) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(4) The maximum continuous output current (IOUT) is determined by device power dissipation limitations. See Power Supply
Recommendations for more details.
6.2 Handling Ratings
MIN
Tstg
Storage temperature range
−65
V(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001, all
pins (1) (2)
Machine Model (MM), per JEDEC specification JESD22-C101, all
pins(2) (3)
MAX
+150
2000
200
(1) JEDEC document JEP155 states that 2000-V HBM allows safe manufacturing with a standard ESD control process.
(2) Human Body Model, 1.5 kΩ in series with 100 pF. Machine Model, 0Ω In series with 200 pF.
(3) JEDEC document JEP157 states that 200-V MM allows safe manufacturing with a standard ESD control process.
UNIT
°C
V
6.3 Recommended Operating Conditions(1)
over operating free-air temperature range (unless otherwise noted)
Operating Temperature Range
Nominal Supply Voltage
MIN
NOM
MAX
−40
+85
4.5
12
(1) The maximum continuous output current (IOUT) is determined by device power dissipation limitations. See Power Supply
Recommendations for more details.
UNIT
°C
V
6.4 Thermal Information
THERMAL METRIC(1)
SOT-23
DBV
SOIC
D08A
UNIT
5 PINS
8 PINS
RθJA
Junction-to-ambient thermal resistance
230°C/W
166°C/W
°C/W
(1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.
4
Submit Documentation Feedback
Copyright © 2003–2014, Texas Instruments Incorporated
Product Folder Links: LMH6723 LMH6724