English
Language : 

LM4050QML_17 Datasheet, PDF (4/18 Pages) Texas Instruments – Precision Micropower Shunt Voltage Reference
LM4050QML
SNVS627G – JUNE 2010 – REVISED JULY 2013
www.ti.com
LM4050-2.5QML Electrical Characteristics SMD: 5962R0923561 (continued)
The initial Reverse Breakdown Voltage tolerance is ±0.1% @ 100μA.
Symbol
Parameter
Conditions
Notes Typical(1) Min
Max
Units
Sub-
groups
IR = 60µA
±3
±15
Average Reverse Breakdown
IR = 100μA
±3
±16
Voltage Temperature
Coefficient
IR = 1mA
See (2)
±3
±18
2
@ 25°C ≤ TA ≤ 125°C
IR = 10mA
±4
±20
ΔVR/ΔT
IR = 15mA
IR = 60µA
±6
±22
ppm/°C
±3
±18
Average Reverse Breakdown
IR = 100μA
±3
±19
Voltage Temperature
Coefficient
IR = 1mA
See (2)
±3.5
±22
3
@ −55°C ≤ TA ≤ 25°C
IR = 10mA
±10
±32
IR = 15mA
±15
±45
ZR
Reverse Dynamic Impedance
IR = 1 mA, f = 120 Hz,
IAC = 0.1 IR
0.3
Ω
0.1 Hz ≤ f ≤ 10 Hz
9
VN
Output Noise Voltage
10 Hz ≤ f ≤ 10KHz
50
μVpp
μVrms
CLOAD
VHYST
Load Capacitor
Thermal Hysteresis
Stable Over Temperature See(3)
60
ΔT = −55°C to 125°C See(4)
1
0
100
µF
ppm
(2) Not tested post irradiation. Typical post irradiation values listed in the post radiation Tempco table.
(3) Capacitive load not required but improves SET stability. This parameter is ensured by design and/or characterization and is not tested in
production.
(4) Thermal hysteresis is defined as the change in voltage measured at +25°C after cycling to temperature -55°C and the 25°C
measurement after cycling to temperature +125°C.
VHYST = lVR1 - VR2l x 106 ppm
VR
Where: VHYST = Thermal hysteresis expressed in ppm
VR = Nominal preset output voltage
VR1 = VR before temperature fluctuation
VR2 = VR after temperature fluctuation.
Post Radiation @ 25°C(1)
The initial Reverse Breakdown Voltage tolerance is ±0.1% @ 100μA. Qualification is performed with a 1.5X overtest. See for
TOTAL IONIZING DOSE details.
Symbol
Parameter
Conditions
30 krad 50 krad
100 krad
Sub-
groups
VR
Reverse Breakdown Voltage
Tolerance
IR = 60μA
IR= 100μA
IR = 1mA
IR = 10mA
IR = 15mA
Max +0.42% +0.67%
+1.75%
1
(1) Pre and post irradiation limits are identical to those listed under electrical characteristics except as listed in the post radiation table.
Post Radiation Tempco(1)
Symbol
Parameter
ΔVR/ΔT
Average Reverse Breakdown Voltage
Temperature Coefficient Drift @ 25°C
≤ TA ≤ 125°C
Average Reverse Breakdown Voltage
Temperature Coefficient Drift @
−55°C ≤ TA ≤ 25°C
Conditions
60μA ≤ IR ≤ 15mA
60μA ≤ IR ≤ 15mA
30 krad
+41
TYPICALS
50 krad
100 krad
+83
+144
+46
+87
+166
(1) Not tested post irradiation. Typical post irradiation values listed in the post radiation Tempco table.
Units
ppm/°C
ppm/°C
4
Submit Documentation Feedback
Product Folder Links: LM4050QML
Copyright © 2010–2013, Texas Instruments Incorporated