English
Language : 

DS16F95_16 Datasheet, PDF (4/16 Pages) Texas Instruments – DS16F95, DS36F95 EIA-485/EIA-422A Differential Bus Transceiver
DS16F95, DS36F95
OBSOLETE
SNLS392D – JUNE 1998 – REVISED APRIL 2013
www.ti.com
Driver Electrical Characteristics(1)(2)
Over recommended supply voltage and operating temperature ranges, unless otherwise specified
Symbol
Parameter
Conditions
Min Typ
VIH
VIL
VOH
VOL
VIC
|VOD1|
|VOD2|
Δ|VOD|
VOC
Δ|VOC|
IO
IIH
IIL
IOS
ICC
Input Voltage HIGH
Input Voltage LOW
Output Voltage HIGH
Output Voltage LOW
Input Clamp Voltage
Differential Output Voltage
Differential Output Voltage
Change in Magnitude of Differential
Output Voltage(3)
Common Mode Output Voltage(4)
Change in Magnitude of Common
Mode Output Voltage(3)
Output Current(5) (Includes
Receiver II)
Input Current HIGH
Input Current LOW
Short Circuit Output Current (6)
Supply Current (Total Package)
IOH = −55 mA
0°C to +70°C
IOL = 55 mA
0°C to +70°C
II = −18 mA
IO = 0 mA
RL = 100Ω, See Figure 1
RL = 54Ω,See Figure 1
RL = 54Ω or 100Ω, See −40°C to +125°C
Figure 1
−55°C to +125°C
Output Disabled
VI = 2.4V
VI = 0.4V
VO = −7.0V
VO = 0V
VO = VCC
VO = +12V
No Load, All Inputs
Open
VO = +12V
VO = −7.0V
DE = 2V, RE = 0.8V
Outputs Enabled
2.0
3.0
2.0 2.25
1.5
2.0
ICCX
DE = 0.8V, RE = 2V
Outputs Disabled
Max
0.8
2.0
−1.3
6.0
±0.2
±0.4
3.0
±0.2
1.0
−0.8
20
−50
−250
−150
150
250
28
25
Units
V
V
V
V
V
V
V
V
V
V
mA
μA
μA
mA
mA
(1) Unless otherwise specified min/max limits apply across the −55°C to +125°C temperature range for the DS16F95 and across the 0°C to
+70°C range for the DS36F95. All typicals are given for VCC = 5V and TA = 25°C.
(2) All currents into the device pins are positive; all currents out of the device pins are negative. All voltages are referenced to ground
unless otherwise specified.
(3) Δ|VOD| and Δ|VOC| are the changes in magnitude of VOD and VOC, respectively, that occur when the input is changed from a high level
to a low level.
(4) In TIA/EIA-422A and TIA/EIA-485 Standards, VOC, which is the average of the two output voltages with respect to ground, is called
output offset voltage, VOS.
(5) Refer to TIA/EIA-485 Standard for exact conditions.
(6) Only one output at a time should be shorted.
4
Submit Documentation Feedback
Copyright © 1998–2013, Texas Instruments Incorporated
Product Folder Links: DS16F95 DS36F95