English
Language : 

CDC328A_09 Datasheet, PDF (4/7 Pages) Texas Instruments – 1Line to 6Line Clock Driver
CDC328A
1ĆLINE TO 6ĆLINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCAS327B − DECEMBER 1992 − REVISED NOVEMBER 1995
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP† MAX UNIT
VIK
VCC = 4.75 V,
II = −18 mA
VOH
VCC = 4.75 V,
IOH = − 48 mA
2
VOL
VCC = 4.75 V,
IOL = 48 mA
II
VCC = 5.25 V,
VI = VCC or GND
IO‡
VCC = 5.25 V,
VO = 2.5 V
−15
ICC
VCC = 5.25 V,
VI = VCC or GND
IO = 0,
Outputs high
Outputs low
Ci
VI = 2.5 V or 0.5 V
† All typical values are at VCC = 5 V, TA = 25°C
‡ Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
−1.2 V
V
0.5 V
±1 µA
−100 mA
10
mA
40
3
pF
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (see Figures 1 and 2)
PARAMETER
tPLH
tPHL
tPLH
tPHL
tsk(o)
tsk(p)
tr
tf
FROM
(INPUT)
A
T/C
A
A
TO
(OUTPUT)
Any Y
Any Y
Any Y (same phase)
Any Y (any phase)
Any Y
Any Y
Any Y
MIN MAX UNIT
1.7
5
ns
1.5
5
1.5
5
ns
1.4
5
0.5
ns
1
1 ns
1.5 ns
1.5 ns
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443