6 Specifications
6.1 Absolute Maximum Ratings
Over-operating free-air temperature range (unless otherwise noted)(1)
VREGIN
VCC
VIOD
VBAT
VI
TA
TF
TSTG
Regulator Input Range
Supply Voltage Range
Open-drain I/O pins (SDA, SCL)
Open-drain I/O pins (ALERT)
BAT Input Pin
TA
Operating free-air temperature range
Functional Temperature Range
Storage temperature range
Lead temperature (soldering, 10 s)
MIN
MAX
UNIT
–0.3
5.5
V
–0.3
2.75
V
–0.3
5.5
V
–0.3
2.75
V
–0.3
5.5
V
–0.3
–40
VCC + 0.3
V
85
°C
–40
10
°C
–65
150
°C
–40
100
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
6.2 ESD Ratings
V(ESD)
Electrostatic
discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
All other pins, per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-C101(2)
VALUE
±1500
±2000
±500
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
6.3 Recommended Operating Conditions
TA =–40°C to 85°C; Typical Values at TA = 25°C CLDO25 = 1.0 μF, and VREGIN = 3.6 V (unless otherwise noted)
MIN
NOM
MAX
VREGIN
Supply Voltage
No operating restrictions
No FLASH writes
2.7
4.5
2.45
2.7
External input capacitor
CREGIN
for internal LDO
between REGIN and
Nominal capacitor values specified.
0.1
VSS
Recommend a 10% ceramic X5R type
External output
capacitor located close to the device.
CLDO25
capacitor for internal
1
LDO between VCC
ICC_WAIT
Gas Gauge in
WAITING mode
GE = High AND GaugeStart() not received or
GaugeStop() Received (GMSEL1,0 = x,x)
15
ICC_ACCU
Gas Gauge in
GE = High AND GaugeStart() received and
ACCUMULATOR mode GaugeStop() not Received (GMSEL1,0 = 0,0)
130
ICC_SOH
State-Of-Health
operating current
GE = High AND GaugeStart() received and
GaugeStop() not Received (GMSEL1,0 = 0,1)
40
ICC_EOS_Burst
End-Of-Service
operating
current—Data Burst
GE = High AND GaugeStart() received and
GaugeStop() not Received (GMSEL1,0 = 1,0)
315
End-Of-Service
ICC_EOS_Gather
operating
current—Data
GE = High AND GaugeStart() AND
GaugeStop() Received (GMSEL1,0 = 1,0)
75
Gathering
VA1
Input voltage range
(VIN, TS)
VSS – 0.05
1
UNIT
V
V
µF
µF
µA
µA
µA
µA
µA
V