English
Language : 

BQ25070 Datasheet, PDF (4/21 Pages) Texas Instruments – 1A, Single-Input, Single-Cell LiFePO4 Linear Battery Charger with 50mA LDO
bq25070
SLUSA66 – JULY 2011
www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
Over junction temperature range 0°C ≤ TJ ≤ 125°C and recommended supply voltage (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
IPRECHARGE
Precharge current to BAT during precharge
mode
VBAT = 0 V to 0.7 V
41.5
45 48.5
RECHARGE OR REFRESH
VRCH
tDGL(RCH)
LDO
Recharge detection threshold
Deglitch time, recharge threshold detected
VBAT falling
VBAT falling to New Charge Cycle
3.1 3.3 3.5
25
VLDO
LDO Output Voltage
ILDO
Maximum LDO Output Current
VDO
Dropout Voltage
CTRL INTERFACE
VIN = 5 V to 10.5 V,
ILDO = 0 mA to 50 mA
VIN = 4.5V, ILDO = 50mA
4.7 4.9 5.1
60
200 350
tCTRL_DGL
CTRL Deglitch timer
tCTRL_LATCH CTRL Latch timer
tHI_MIN
High Duration on CTRL
tLO_MIN
Low Time Duration on CTRL
RPULLDOWN CTRL Pulldown Resistor
LOGIC LEVELS ON CTRL
5
2
50
1000
50
1000
260
VIL
Logic LOW input voltage
VIH
Logic HIGH input voltage
BATTERY-PACK NTC MONITOR (TS)
0.4
1.4
VCOLD
TS Cold Threshold
VCUTOFF
TS Cold Cutoff Threshold
VHOT
TS Hot Threshold
VHOT_HYS
TS Hot Cutoff Threshold
tdgl(TS)
Deglitch for TS Fault
CHG OUTPUT
VTS Rising
VTS Falling
VTS Falling
VTS Rising
Fault detected on TS to stop charge
24.5
25 25.5
1
12 12.5
13
1
25
VOL
Output LOW voltage
IIH
Leakage current
tFLSH(TS)
TS fault flash period
THERMAL REGULATION
ISINK = 1 mA
CHG = 5 V
50% Duty Cycle, TS out of valid range
0.45
1
100
TJ(REG)
Temperature Regulation Limit
TJ rising
125
TJ(OFF)
Thermal shutdown temperature
TJ rising
155
TJ(OFF-HYS) Thermal shutdown hysteresis
TJ falling
20
UNITS
mA
V
ms
V
mA
mV
ms
ms
μs
μs
kΩ
V
V
%VLDO
%VLDO
%VLDO
%VLDO
ms
V
μA
ms
C
C
C
4