74AC11374_14 Datasheet, PDF (4/11 Pages) Texas Instruments – OCTAL D-TYPE EDGE-TRIGGERED FLIP-FLOP WITH 3-STATE OUTPUTS
74AC11374
OCTAL D-TYPE EDGE-TRIGGERED FLIP-FLOP
WITH 3-STATE OUTPUTS
SCAS214A − JULY 1987 − REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA = 25°C
VCC
MIN TYP MAX
3 V 2.9
IOH = −50 mA
4.5 V 4.4
5.5 V 5.4
VOH
IOH = −4 mA
IOH = −24 mA
3 V 2.58
4.5 V 3.94
5.5 V 4.94
IOH = −75 mA{
5.5 V
3V
0.1
IOL = 50 mA
4.5 V
0.1
5.5 V
0.1
VOL
IOL = 12 mA
IOL = 24 mA
3V
0.36
4.5 V
0.36
5.5 V
0.36
IOL = 75 mA{
5.5 V
IOZ
VO = VCC or GND
5.5 V
±0.5
II
VI = VCC or GND
5.5 V
±0.1
ICC
VI = VCC or GND,
IO = 0
5.5 V
8
Ci
VI = VCC or GND
5V
4
Co
VO = VCC or GND
5V
10
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
MIN MAX UNIT
2.9
4.4
5.4
2.48
V
3.8
4.8
3.85
0.1
0.1
0.1
0.44 V
0.44
0.44
1.65
±5 mA
±1 mA
80 mA
pF
pF
timing requirements over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
TA = 25°C
MIN MAX
MIN MAX UNIT
fclock
tw
tsu
th
Clock frequency
Pulse duration
Setup time, data before CLK↑
Hold time, data after CLK↑
CLK low or high
0
75
0
75 MHz
6.5
6.5
ns
2.5
2.5
ns
4.5
4.5
ns
timing requirements over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
TA = 25°C
MIN MAX
MIN MAX UNIT
fclock
tw
tsu
th
Clock frequency
Pulse duration
Setup time, data before CLK↑
Hold time, data after CLK↑
CLK low or high
0
95
0
95 MHz
5
5
ns
2.5
2.5
ns
3.5
3.5
ns
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265