TLC27L4, TLC27L4A, TLC27L4B, TLC27L4Y, TLC27L9
LinCMOS™ PRECISION QUAD OPERATIONAL AMPLIFIERS
SLOS053C – OCTOBER 1987 – REVISED AUGUST 1994
APPLICATION INFORMATION
latch-up (continued)
The current path established if latch-up occurs is usually between the positive supply rail and ground and can
be triggered by surges on the supply lines and/or voltages on either the output or inputs that exceed the supply
voltage. Once latch-up occurs, the current flow is limited only by the impedance of the power supply and the
forward resistance of the parasitic thyristor and usually results in the destruction of the device. The chance of
latch-up occurring increases with increasing temperature and supply voltages.
500 kΩ
5V
1/4
+
TLC27L4
–
VO1
0.1 µF
500 kΩ
–
+
1/4
TLC27L4
500 kΩ
VO2
500 kΩ
Figure 44. Multivibrator
100 kΩ
100 kΩ
Set
VDD
+
VO
Reset
100 kΩ
–
1/4
TLC27L4
33 kΩ
NOTE: VDD = 5 V to 16 V
Figure 45. Set /Reset Flip-Flop
34