Thermal Considerations
The thermal characteristics of the device are specified using
the parameter θJA, which relates the junction temperature to
the ambient temperature. Although the value of θJA is depen-
dent on many variables, it still can be used to approximate the
operating junction temperature of the device. To obtain an
estimate of the device junction temperature, one may use the
following relationship:
TJ = PD x θJA + TA where:
PD is the total power dissipation of the device;
TJ is the junction temperature in °C;
 θJA is the junction-to-ambient thermal resistance for the de-
vice;
TA is the ambient temperature in °C.
It is important to always keep the operating junction temper-
ature (TJ) below 105°C for reliable operation. If the junction
temperature exceeds 160°C the device will cycle in and out
of thermal shutdown. If thermal shutdown occurs it is a sign
of inadequate heat sinking or excessive power dissipation in
the device.
The figure below provides a better approximation of the θJA
for a given PCB copper area. The PCB heatsink area consists
of 2oz. copper located on the bottom layer of the PCB directly
under the exposed pad. The bottom copper area is connected
to the exposed pad by means of a 4 x 4 array of 12 mil thermal
vias.
30112145
FIGURE 15. Thermal Resistance vs. PCB Area