BQ27505-J3 Datasheet, PDF (33/44 Pages) Texas Instruments – System-Side Impedance Track™ Fuel Gauge
Not Recommended for New Designs
bq27505-J3
www.ti.com
SLUS986A – OCTOBER 2009 – REVISED FEBRUARY 2010
5.7.4 SLEEP+ MODE
Compared to the SLEEP mode, SLEEP+ mode has the high frequency oscillator in operation. The
communication delay could be eliminated. The SLEEP+ is entered automatically if the feature is enabled
(CONTROL STATUS [SNOOZE] = 1) and AverageCurrent( ) is below the programmable level Sleep
Current.
During SLEEP+ mode, the bq27505 periodically takes data measurements and updates its data set.
However, a majority of its time is spent in an idle condition.
The bq27505 exits SLEEP+ if any entry condition is broken, specifically when (1) any communication
activity with the gauge, or (2) AverageCurrent( ) rises above Sleep Current, or (3) a current in excess of
IWAKE through RSENSE is detected.
5.7.5 HIBERNATE MODE
HIBERNATE mode should be used when the system equipment needs to enter a low-power state, and
minimal gauge power consumption is required. This mode is ideal when a system equipment is set to its
own HIBERNATE, SHUTDOWN, or OFF modes.
Before the fuel gauge can enter HIBERNATE mode, the system must set the [HIBERNATE] bit of the
CONTROL_STATUS register. The gauge waits to enter HIBERNATE mode until it has taken a valid OCV
measurement and the magnitude of the average cell current has fallen below Hibernate Current. The
gauge can also enter HIBERNATE mode if the cell voltage falls below Hibernate Voltage and a valid
OCV measurement has been taken. The gauge will remain in HIBERNATE mode until the system issues a
direct I2C command to the gauge or a POR occurs. I2C Communication that is not directed to the gauge
will not wake the gauge.
It is important that BAT_GD be deserted status (no battery charging/discharging). This prevents a charger
application from inadvertently charging the battery before an OCV reading can be taken. It is the system’s
responsibility to wake the bq27505 after it has gone into HIBERNATE mode. After waking, the gauge can
proceed with the initialization of the battery information (OCV, profile selection, etc.)
5.8 POWER CONTROL
5.8.1 WAKE-UP COMPARATOR
The wake up comparator is used to indicate a change in cell current while the bq27505 is in SLEEP mode.
Operation Configuration uses bits [RSNS1–RSNS0] to set the sense resistor selection. Operation
Configuration also uses the [IWAKE] bit to select one of two possible voltage threshold ranges for the
given sense resistor selection. An internal interrupt is generated when the threshold is breached in either
the charge or discharge direction. Setting both [RSNS1] and [RSNS0] to 0 disables this feature.