TLC5540_14 Datasheet, PDF (3/24 Pages) Texas Instruments – 8-Bit Resolution Differential Linearity Error Integral Linearity Error
TLC5540
www.ti.com
SLAS105D − JANUARY 1995 − REVISED APRIL 2004
Terminal Functions
TERMINAL
NAME
NO.
AGND
20, 21
ANALOG IN
19
CLK
12
DGND
2, 24
D1 −D8
3 −10
OE
1
VDDA
VDDD
REFB
14, 15, 18
11, 13
23
REFBS
22
REFT
17
REFTS
16
I/O
DESCRIPTION
Analog ground
I Analog input
I Clock input
Digital ground
O Digital data out. D1:LSB, D8:MSB
I Output enable. When OE = L, data is enabled. When OE = H, D1−D8 is high impedance.
Analog VDD
Digital VDD
I ADC reference voltage in (bottom)
Reference voltage (bottom). When using the internal voltage divider to generate a nominal 2-V reference, the
REFBS terminal is shorted to the REFB terminal and the REFTS terminal is shorted to the REFT terminal (see
Figure 13 and Figure 14).
I Reference voltage in (top)
Reference voltage (top). When using the internal voltage divider to generate a nominal 2-V reference, the
REFTS terminal is shorted to the REFT terminal and the REFBS terminal is shorted to the REFB terminal (see
Figure 13 and Figure 14).
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VDDA, VDDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Reference voltage input range, VI(REFT), VI(REFB), VI(REFBS), VI(REFTS) . . . . . . . . . . . . . . . . AGND to VDDA
Analog input voltage range, VI(ANLG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AGND to VDDA
Digital input voltage range, VI(DGTL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DGND to VDDD
Digital output voltage range, VO(DGTL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DGND to VDDD
Operating free-air temperature range, TA: TLC5540C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLC5540I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
3