English
Language : 

TLC542C_14 Datasheet, PDF (3/13 Pages) Texas Instruments – 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL AND 11 INPUTS
operating sequence
I/O
CLOCK
tsu(A)
tsu(CS)
CS
1 2 3 4 56 7 8
Access
Cycle B
(see Note A)
tacq
TLC542C, TLC542I
8-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL AND 11 INPUTS
SLAS075C – FEBRUARY 1989 – REVISED JUNE 2001
1 2 3 4 56 7 8
Don’t Care
tc(1)
Access
Cycle C
12 Internal System Clocks ≤ 12 µs
t(acq)
ADDRESS
INPUT
DATA
OUT
EOC
MSB
LSB
B3 B2 B1 B0
Don’t Care
A7
A6 A5 A4 A3 A2 A1 A0
Previous Conversion Data A
MSB
(see Note B)
LSB
td(I/O–EOC)
Hi-Z State
See Note B
td(EOC–DATA)
tc(2)
MSB
LSB
C3 C2 C1 C0
Don’t Care
B7 B6 B5 B4 B3 B2 B1 B0
MSB
Conversion Data B
LSB
Hi-Z
State
NOTES: A. To minimize errors caused by noise at the chip select input, the internal circuitry waits for two rising edges and one falling edge
of the internal system clock after CS↓ before responding to control input signals. The CS setup time is given by the tsu(CS)
specifications. Therefore, no attempt should be made to clock-in an address until the minimum chip select setup time has elapsed.
B. The output becomes 3-state on CS going high or on the negative edge of the eighth I/O clock.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 V
Input voltage range (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Output voltage range, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Peak input current range (any input), Ip-p) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Peak total input current (all inputs), IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±30 mA
Operating free-air temperature range: TLC542C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLC542l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Case temperature for 10 seconds, TC: FN package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: DW or N package . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to digital ground with REF– and GND wired together (unless otherwise noted).
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3