SN74CB3T1G125-Q1 Datasheet, PDF (3/13 Pages) Texas Instruments – SINGLE FET BUS SWITCH 2.5-V/3.3-V LOW-VOLTAGE SWITCH WITH 5-V-TOLERANT LEVEL SHIFTER
www.ti.com
SN74CB3T1G125-Q1
SIMPLIFIED SCHEMATIC, EACH FET SWITCH (SW)
SCDS319 – JUNE 2011
A
B
VG(1)
Control
Circuit
EN(2)
(1) Gate voltage (VG) is equal to approximately VCC + VT when the switch is ON
and VI > VCC + VT.
(2) EN is the internal enable signal applied to the switch.
ABSOLUTE MAXIMUM RATINGS(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
VCC
Supply voltage range
VIN
Control input voltage range(2) (3)
VI/O
Switch I/O voltage range(2) (3) (4)
IIK
Control input clamp current
II/OK
I/O port clamp current
IIO
ON-state switch current(5)
Continuous current through VCC or GND
θJA
Package thermal impedance(6)
Tstg
Storage temperature range
VIN < 0
VI/O < 0
DCK package
–0.5
7
V
–0.5
7
V
–0.5
7
V
–50 mA
–50 mA
±128 mA
±100 mA
252 °C/W
–65
150
°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground, unless otherwise specified.
(3) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
(4) VI and VO are used to denote specific conditions for VI/O.
(5) II and IO are used to denote specific conditions for II/O.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS(1)
MIN MAX UNIT
VCC
Supply voltage
VIH
High-level control input voltage
VIL
Low-level control input voltage
VI/O
Data input/output voltage
TA
Operating free-air temperature
VCC = 2.3 V to 2.7 V
VCC = 2.7 V to 3.6 V
VCC = 2.3 V to 2.7 V
VCC = 2.7 V to 3.6 V
2.3 3.6 V
1.7 5.5
V
2 5.5
0 0.7
V
0 0.8
0 5.5 V
–40 125 °C
(1) All unused control inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Copyright © 2011, Texas Instruments Incorporated
3