English
Language : 

OPA4684M Datasheet, PDF (3/32 Pages) Texas Instruments – QUAD LOW-POWER CURRENT-FEEDBACK OPERATIONAL AMPLIFIER
OPA4684M
QUAD LOWĆPOWER CURRENTĆFEEDBACK
OPERATIONAL AMPLIFIER
SGLS145B − AUGUST 2003 − REVISED FEBRUARY 2004
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6.5 V
Internal power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Thermal information
Differential input voltage, VID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1.2 V
Input voltage range, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±VS
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300°C
Junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175°C
ESD rating: HBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 kV
CDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 kV
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
Operating voltage
Single-supply operating voltage
Operating free-air temperature
MIN NOM MAX UNIT
±5
±6 V
5
12 V
−55
125 °C
electrical characteristics, VS = ±5 V, RF = 800 Ω, RL = 100 Ω, G = +2 (unless otherwise noted) (see
Note 1)
PARAMETER
TEST CONDITIONS
AC Performance (See Figure 41)
Small signal bandwidth (VO =
0.5 Vp-p)
Large signal bandwidth
Rise and fall time
Differential gain
Differential phase
All hostile cross talk, input
referred
G = +1, RF = 800 Ω
G = +5, RF = 800 Ω
G = +10, RF = 800 Ω
G = +20, RF = 800 Ω
VO = 4 V, G = +2
VO = 0.5 V step, G = +2
VO = 4 V step, G = +2
VO = 1.4 V, G = +2, RL = 150 Ω , NTSC
VO = 1.4 V, G = +2, RL = 150 Ω , NTSC
3 channels driven at 5 MHz, VI = 1 V,
4th channel measured
MIN TYP MAX UNIT
250
138
120
95
90
3
6.8
0.04%
0.02°
−52
MHz
MHz
ns
dB
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265