electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP† MAX UNIT
VIK
VCC = 4.75 V,
II = −18 mA
VOH
VCC = 4.75 V,
IOH = − 15 mA
2.5
VOL
VCC = 4.75 V,
IOL = 64 mA
II
VCC = 5.25 V,
VI = VCC or GND
IO‡
VCC = 5.25 V,
VO = 2.5 V
−15
ICC
VCC = 5.25 V,
VI = VCC or GND
IO = 0,
Outputs high
Outputs low
Ci
VI = 2.5 V or 0.5 V
† All typical values are at VCC = 5 V, TA = 25°C
‡ Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
−1.2 V
V
0.55 V
±1 µA
−100 mA
50 µA
20
30 mA
3
pF
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (see Figures 1 and 2)
PARAMETER
tPLH
tPHL
tPLH
tPHL
tsk(o)
tr
tf
FROM
(INPUT)
A
T/C
A
TO
(OUTPUT)
Any Y
Any Y
Any Y (same phase)
Any Y (any phase)
MIN TYP MAX UNIT
1.7
7
ns
1.5
5.4
1.5
8
ns
1.4
6.6
0.7
ns
2.6
1.2
ns
0.5
ns
switching characteristics, VCC = 5 V ± 0.25 V, TA = 25°C to 70°C (see Figures 1 and 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN MAX
tPLH
A
tPHL
tsk(o)
A
Any Y
Any Y (same phase)
Any Y (any phase)
2.1 6.1
1.7 4.8
0.7
2.1
UNIT
ns
ns