CDC328 Datasheet, PDF (2/7 Pages) Texas Instruments – 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY
CDC328
1ĆLINE TO 6ĆLINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCBS116B − JANUARY 1991 − REVISED MARCH 1994
logic diagram (positive logic)
15
1T/C
16 1Y1
13
2T/C
12
A
10
3T/C
4T/C 9
2
1Y2
3
2Y1
5
2Y2
6
3Y
8
4Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Voltage range applied to any output in the high state
or power-off state, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −18 mA
Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50 mA
Continuous total power dissipation at (or below) 25°C free-air temperature (see Note 2) . . . . . . . . 1000 mW
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. For operation above 25°C free-air temperature, derate to 478 mW at 85°C at the rate of 8.7 mW/°C.
recommended operating conditions (see Note 3)
VCC
VIH
VIL
VI
IOH
IOL
∆t / ∆v
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
High-level output current
Low-level output current
Input transition rise or fall rate
fclock Input clock frequency
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low.
MIN NOM
4.75
5
2
0
− 40
MAX
5.25
0.8
VCC
−15
64
5
80
85
UNIT
V
V
V
V
mA
mA
ns / V
MHz
°C
2−2