English
Language : 

CD74FCT240_16 Datasheet, PDF (3/12 Pages) Texas Instruments – BiCMOS OCTAL BUFFER/LINE DRIVER WITH 3-STATE OUTPUTS
CD74FCT240
BiCMOS OCTAL BUFFER/LINE DRIVER
WITH 3-STATE OUTPUTS
SCBS729 − JULY 2000
recommended operating conditions (see Note 2)
MIN MAX UNIT
VCC
VIH
VIL
VI
VO
IOH
IOL
Δt/Δv
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
High-level output current
Low-level output current
Input transition rise or fall rate (slew rate)
4.75
2
0
0
0
5.25
0.8
VCC
VCC
−15
64
10
V
V
V
V
V
mA
mA
ns/V
TA
Operating free-air temperature
0
70 °C
NOTE 2: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA = 25°C
VCC
MIN
MIN MAX
VIK
VOH
VOL
II
IOZ
IOS†
ICC
ΔICC‡
II = −18 mA
IOH = −15 mA
IOL = 64 mA
VI = VCC or GND
VO = VCC or GND
VI = VCC or GND,
VI = VCC or GND,
One input at 3.4 V,
Other inputs at VCC or GND
VO = 0
IO = 0
4.75 V
4.75 V
4.75 V
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
−1.2
2.4
2.4
0.55
±0.1
±0.5
−60
−60
8
1.6
Ci
VI = VCC or GND
10
Co
VO = VCC or GND
15
† Not more than one output should be tested at a time, and the duration of the test should not exceed 100 ms.
‡ This is the increase in supply current for each input at one of the specified TTL voltage levels rather than 0 V or VCC.
MAX
−1.2
0.55
±1
±10
80
1.6
10
15
UNIT
V
V
V
mA
mA
mA
mA
mA
pF
pF
switching characteristics over recommended operating
VCC = 5 V ± 0.25 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tpd
A
Y
ten
OE
Y
tdis
OE
Y
free-air temperature range,
TA = 25°C
TYP
5
7
6
MIN MAX UNIT
1.5
8 ns
1.5
10 ns
1.5 9.5 ns
noise characteristics, VCC = 5 V, CL = 50 pF, TA = 25°C
PARAMETER
VOL(P)
VOH(V)
VIH(D)
VIL(D)
Quiet output, maximum dynamic VOL
Quiet output, minimum dynamic VOH
High-level dynamic input voltage
Low-level dynamic input voltage
MIN TYP MAX UNIT
1
V
0.5
V
2
V
0.8 V
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3