74ACT11533 Datasheet, PDF (3/7 Pages) Texas Instruments – OCTAL D-TYPE TRANSPARENT LATCHES WITH 3-STATE OUTPUTS | |||
|
◁ |
Ä
recommended operating conditions
VCC
VIH
VIL
VI
VO
IOH
IOL
Dt /Dv
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
54ACT11533, 74ACT11533
OCTAL DÄTYPE TRANSPARENT LATCHES
WITH 3ÄSTATE OUTPUTS
SCAS017A â D2957, JULY 1987 â REVISED APRIL 1993
54ACT11533
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 VCC
â 24
24
0
10
â55 125
74ACT11533
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 VCC
â 24
24
0
10
â 40
85
UNIT
V
V
V
V
V
mA
mA
ns/ V
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
54ACT11533 74ACT11533
MIN TYP MAX MIN MAX MIN MAX
IOH = â 50 mA
4.5 V
4.4
5.5 V
5.4
4.4
4.4
5.4
5.4
VOH
IOH = â 24 mA
4.5 V 3.94
5.5 V 4.94
3.7
3.8
4.7
4.8
IOH = â 50 mA{
IOH = â 75 mA{
IOL = 50 mA
5.5 V
5.5 V
4.5 V
5.5 V
3.85
3.85
0.1
0.1
0.1
0.1
0.1
0.1
VOL
IOL = 24 mA
4.5 V
5.5 V
0.36
0.5
0.44
0.36
0.5
0.44
IOL = 50 mA{
IOL = 75 mA{
5.5 V
5.5 V
1.65
1.65
IOZ
VO = VCC or GND
5.5 V
± 0.5
± 10
±5
II
VI = VCC or GND
5.5 V
± 0.1
±1
±1
ICC
VI = VCC or GND, IO = 0
5.5 V
8
160
80
DICC}
One input at 3.4 V,
Other inputs at GND or VCC
5.5 V
0.9
1
1
Ci
VI = VCC or GND
5V
4
Co
VO = VCC or GND
5V
10
â Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
â¡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
UNIT
V
V
mA
mA
mA
mA
pF
pF
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
2â3
|
▷ |