English
Language : 

74ACT11533 Datasheet, PDF (3/7 Pages) Texas Instruments – OCTAL D-TYPE TRANSPARENT LATCHES WITH 3-STATE OUTPUTS
ą
recommended operating conditions
VCC
VIH
VIL
VI
VO
IOH
IOL
Dt /Dv
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
54ACT11533, 74ACT11533
OCTAL DĆTYPE TRANSPARENT LATCHES
WITH 3ĆSTATE OUTPUTS
SCAS017A − D2957, JULY 1987 − REVISED APRIL 1993
54ACT11533
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 VCC
− 24
24
0
10
−55 125
74ACT11533
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 VCC
− 24
24
0
10
− 40
85
UNIT
V
V
V
V
V
mA
mA
ns/ V
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
54ACT11533 74ACT11533
MIN TYP MAX MIN MAX MIN MAX
IOH = − 50 mA
4.5 V
4.4
5.5 V
5.4
4.4
4.4
5.4
5.4
VOH
IOH = − 24 mA
4.5 V 3.94
5.5 V 4.94
3.7
3.8
4.7
4.8
IOH = − 50 mA{
IOH = − 75 mA{
IOL = 50 mA
5.5 V
5.5 V
4.5 V
5.5 V
3.85
3.85
0.1
0.1
0.1
0.1
0.1
0.1
VOL
IOL = 24 mA
4.5 V
5.5 V
0.36
0.5
0.44
0.36
0.5
0.44
IOL = 50 mA{
IOL = 75 mA{
5.5 V
5.5 V
1.65
1.65
IOZ
VO = VCC or GND
5.5 V
± 0.5
± 10
±5
II
VI = VCC or GND
5.5 V
± 0.1
±1
±1
ICC
VI = VCC or GND, IO = 0
5.5 V
8
160
80
DICC}
One input at 3.4 V,
Other inputs at GND or VCC
5.5 V
0.9
1
1
Ci
VI = VCC or GND
5V
4
Co
VO = VCC or GND
5V
10
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
UNIT
V
V
mA
mA
mA
mA
pF
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
2−3