TLC3574_14 Datasheet, PDF (29/50 Pages) Texas Instruments – 14-Bit Resolution for TLC3574/78, 12-Bit for TLC2574/2578 | |||
|
◁ |
TLC3574, TLC3578, TLC2574, TLC2578
5ÄV ANALOG, 3Ä/5ÄV DIGITAL, 14Ä/12ÄBIT, 200ÄKSPS, 4Ä/8ÄCHANNEL
SERIAL ANALOGÄTOÄDIGITAL CONVERTERS WITH ±10ÄV INPUTS
SLAS262C â OCTOBER 2000 â REVISED MAY 2003
conversion operation (continued)
CS Tied to Low
Select Channel
16 SCLK
t(sample)
Select Channel
16 SCLK
CSTART
Possible
FS
Signal
t(convert)
SDÃI ÃÃÃ*****ÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃ** ÃÃÃÃÃÃÃ
INT
EOC
OR
SDO
Previous Conversion Result
Hi-Z
Data Lost
Hi-Z
Conversion Result
Hi-Z
Possible Signal
** Select Channel
ÃÃÃÃ Donât Care
Figure 13. Mode 00, CSTART Triggers Sampling/Conversion, FS Initiates Select
CS
FS
SDI
ÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃ ÃÃÃÃÃÃÃÃ SDO
ÃÃÃÃÃÃÃ ÃÃÃ INT
Select CH1
Select Any
Channel
Select CH2
Select Any
Channel
***
**
**
*
*
**
**
*
*
DATA1 of CH1 DATA2 of CH1
Hi-Z
1/4 FIFO FULL
DATA1 of CH2 DATA2 of CH2
1/4 FIFO FULL
Donât Care
Possible Signal
MODE 01, FS Activates Conversion, FIFO Threshold = 1/4 Full
*** ââ WRITE CFR
Read FIFO After Threshold Is Hit
** ââ Select Channel
* ââ FIFO Read
Figure 14. Mode 01, FS Initiates Operations
CS
FS
CSTART
SDI
ÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃ SDO
Select CH1
***
**
Select CH2
*
*
**
*
*
Hi-Z
1/4 FIFO FULL
DATA1 of CH1 DATA2 of CH1
1/4 FIFO FULL
DATA1 of CH2 DATA2 of CH2
ÃÃ INT
Donât Care
Possible Signal
*** ââ WRITE CFR
** ââ Select Channel
* ââ FIFO Read
MODE 01, FS Initiates Select Period, CSTART Activates Conversion, FIFO Threshold = 1/4 Full,
Read FIFO After Threshold Is Hit
Figure 15. Mode 01, CSTART Triggers Samplings/Conversions
WWW.TI.COM
29
|
▷ |