Thermal Design Considerations (continued)
Maximum power dissipation allowed by the package is calculated by Equation 6.
PPKG
=
TJ(max) - TA(max)
qJA
where
•
•
•
TJ(max) is 125°C.
TA(max) is the maximum ambient temperature in the system.
θJA is the thermal resistance from junction to ambient.
TPS51200-EP
SLUSA48 – JUNE 2016
(6)
NOTE
Because Equation 6 demonstrates the effects of heat spreading in the ground plane, use it
as a guideline only. Do not use Equation 6 to estimate actual thermal performance in real
application environments.
In an application where the device is mounted on PCB, TI strongly recommends using ψJT and ψJB, as explained
in the section pertaining to estimating junction temperature in the Semiconductor and IC Package Thermal
Metrics application report, SPRA953. Using the thermal metrics ψJT and ψJB, as shown in the Thermal
Information table, estimate the junction temperature with corresponding formulas shown in Equation 7. The older
θJC top parameter specification is listed as well for the convenience of backward compatibility.
TJ = TT + YJT ´ PD
(7)
TJ = TB + YJB ´ PD
where
• PD is the power dissipation shown in Equation 4 and Equation 5.
• TT is the temperature at the center-top of the IC package.
• TB is the PCB temperature measured 1-mm away from the thermal pad package on the PCB surface (see
Figure 32).
(8)
NOTE
Both TT and TB can be measured on actual application boards using a thermo-gun (an
infrared thermometer). For more information about measuring TT and TB, see the
application report Using New Thermal Metrics (SBVA025).
.
Land Pad
3 mm x 1.9 mm
TT on top of package
TB on PCB surface
Exposed Thermal
Die Pad,
2.48 mm x 1.74 mm
UDG-08018
1 mm
Figure 31. Recommended Land Pad Pattern
Figure 32. Package Thermal Measurement