SPNZ187 Datasheet, PDF (24/36 Pages) Texas Instruments – This document describes the known exceptions to the functional specifications for the device.
DEVICE#070 — Some multiplexing controls are not compatible with the emulation device
www.ti.com
DEVICE#070
Some multiplexing controls are not compatible with the emulation device
Severity
Expected Behavior
Issue
Conditions
Implications
Workaround(s)
Medium
For the common functions, it is expected that the derivative parts will maintain
compatibility to the superset emulation part.
There are multiple issues with the multiplexing controls:
1. For GIOB[2], to take input from the alternate path,the PINMMR29[16] has to cleared.
This is incompatible with the emulation device, where the PINMMR29[16] needs to
be set to select the alternate path as input for GIOB[2].
2. PINMMR29[24] is cleared by default to select MII interface for the EMAC. This is
incompatible with the emulation device, where the PINMMR29[24] was set by default
and selects the RMII interface.
The behavior is not dependent on any particular operating condition.
The application must manage the configuration of the PINMMR registers based on the
actual part being used. The code running on the emulation device cannot be run as-is on
this device.
There are no software workarounds.
24
RM46x Microcontroller
Copyright © 2012, Texas Instruments Incorporated
SPNZ187 – September 2012
Submit Documentation Feedback