English
Language : 

MSP430AFE2X3_17 Datasheet, PDF (23/50 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
www.ti.com
MSP430AFE2x3
MSP430AFE2x2
MSP430AFE2x1
SLAS701A – NOVEMBER 2010 – REVISED MARCH 2011
Supply Voltage Supervisor (SVS) / Supply Voltage Monitor (SVM)(1)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
t(SVSR)
td(SVSon)
tsettle
V(SVSstart)
Vhys(SVS_IT-)
dVCC/dt > 30 V/ms (see Figure 12)
dVCC/dt ≤ 30 V/ms
SVS on, switch from VLD = 0 to VLD ≉ 0, VCC =3 V
VLD ≉ 0(2)
VLD ≉ 0, VCC/dt ≤ 3 V/s (see Figure 12)
VCC/dt ≤ 3 V/s (see Figure 12)
VCC/dt ≤ 3 V/s (see Figure 12), external voltage applied on
SVSIN
VLD = 1
VLD = 2 to 14
VLD = 15
100
2000
100
12
1.55
120
15
10
µs
µs
µs
1.7 V
mV
mV
mV
VLD = 1
1.8 1.9 2.05
VLD = 2
2.1
VLD = 3
2.2
VLD = 4
2.3
VLD = 5
2.24 2.4 2.6
VLD = 6
2.5
V(SVS_IT-)
VCC/dt ≤ 3V/s (see Figure 12)
VLD = 7
VLD = 8
VLD = 9
2.65
2.8
V
2.69 2.9 3.13
VLD = 10
3.05
VLD = 11
3.2
VLD = 12
VLD = 13
VLD = 14
3.24
3.35
3.5 3.76(3)
3.7 (3)
ICC(SVS) (1)
VCC/dt ≤ 3 V/s (see Figure 12), external voltage applied on
SVSIN
VLD ≠ 0, VCC = 3 V
VLD = 15
1.1 1.2 1.3
12
17 µA
(1) The current consumption of the SVS module is not included in the ICC current consumption data.
(2) tsettle is the settling time that the comparator o/p needs to have a stable level after VLD is switched VLD ≉ 0 to a different VLD value
somewhere between 2 and 15. The overdrive is assumed to be > 50 mV.
(3) The recommended operating voltage range is limited to 3.6 V.
Copyright © 2010–2011, Texas Instruments Incorporated
Submit Documentation Feedback
23