LM12454_14 Datasheet, PDF (22/45 Pages) Texas Instruments – LM12454/LM12458/LM12H458 12-Bit + Sign Data Acquisition System with Self-Calibration
LM12454, LM12458, LM12H458
SNAS079A – MAY 2004 – REVISED FEBRUARY 2006
www.ti.com
Figure 10. TRI-STATE Test Circuits and Waveforms
Timing Diagrams
VA+ = VD+ = +5V, tR = tF = 3 ns, CL = 100 pF for the INT, DMARQ, D0–D15 outputs.
Figure 11. Multiplexed Data Bus
1, 3: CS or Address valid to ALE low set-up time.
2, 4: CS or Address valid to ALE low hold time.
5: ALE pulse width
6: RD high to next ALE high
7: ALE low to RD low
22
Submit Documentation Feedback
Copyright © 2004–2006, Texas Instruments Incorporated