English
Language : 

TAS5414B-Q1_16 Datasheet, PDF (21/46 Pages) Texas Instruments – FOUR-CHANNEL AUTOMOTIVE DIGITAL AMPLIFIERS
www.ti.com
DESCRIPTION
TAS5414B-Q1/5424B 0
(OSC MASTER)
TAS5414B-Q1/5424B 1
(OSC SLAVE1)
TAS5414B-Q1/5424B 2
(OSC SLAVE2)
TAS5414B-Q1/5424B 3
(OSC SLAVE3)
I2C WRITE
I2C READ
I2C WRITE
I2C READ
I2C WRITE
I2C READ
I2C WRITE
I2C READ
Table 3. TAS5414B-Q1/5424 I2C Addresses
FIXED ADDRESS
MSB 6
5
4
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
SELECTABLE WITH
ADDRESS PIN
3
2
1
1
0
0
1
0
0
1
0
1
1
0
1
1
1
0
1
1
0
1
1
1
1
1
1
TAS5414B-Q1
TAS5424B-Q1
SLOS673 – DECEMBER 2011
READ/WRITE
BIT
LSB
0
1
0
1
0
1
0
1
I2C
ADDRESS
0xD8
0xD9
0xDA
0xDB
0xDC
0xDD
0xDE
0xDF
ADDRESS
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E, 0x0F
0x10
0x13
Table 4. I2C Address Register Definitions
R/W
REGISTER DESCRIPTION
R
Latched fault register 1, global and channel fault
R
Latched fault register 2, dc offset and overcurrent detect
R
Latched diagnostic register 1, load diagnostics
R
Latched diagnostic register 2, load diagnostics
R
External status register 1, temperature and voltage detect
R
External status register 2, Hi-Z and low-low state
R
External status register 3, mute and play modes
R
External status register 4, load diagnostics
R/W
External control register 1, channel gain select
R/W
External control register 2, over current control
R/W
External control register 3, switching frequency and clip pin select
R/W
External control register 4, load diagnostic, master mode select
R/W
External control register 5, output state control
R/W
External control register 6, output state control
-
Not Used
R/W
External control register 7, DC detect threshold selection
R
External status register 5, over temperature shutdown and thermal foldback
Table 5. Fault Register 1 (0x00) Protection
D7 D6 D5 D4 D3 D2 D1 D0
FUNCTION
0
0
0
0
0
0
0
0 No protection-created faults, default value
–
–
–
–
–
–
–
1 Overtemperature warning has occurred
–
–
–
–
–
–
1
– DC offset has occurred in any channel
–
–
–
–
–
1
–
– Overcurrent shutdown has occurred in any channel
–
–
–
–
1
–
–
– Overtemperature shutdown has occurred
–
–
–
1
–
–
–
– Charge pump undervoltage has occurred
–
–
1
–
–
–
–
– AVDD, analog voltage, undervoltage has occurred
–
1
–
–
–
–
–
– PVDD undervoltage has occurred
1
–
–
–
–
–
–
– PVDD overvoltage has occurred
Table 6. Fault Register 2 (0x01) Protection
D7 D6 D5 D4 D3 D2 D1 D0
FUNCTION
0
0
0
0
0
0
0
0 No protection-created faults, default value
–
–
–
–
–
–
–
1 Overcurrent shutdown channel 1 has occurred
Copyright © 2011, Texas Instruments Incorporated
21