English
Language : 

MUX506 Datasheet, PDF (20/38 Pages) Texas Instruments – 36-V, Low-Capacitance, Low-Leakage-Current, Precision Analog Multiplexers
MUX506, MUX507
SBAS803 – NOVEMBER 2016
www.ti.com
7.7 Turn-On and Turn-Off Time
Turn-on time is defined as the time taken by the output of the MUX50x to rise to 90% final value after the enable
signal has risen to 50% final value. Figure 31 shows the setup used to measure turn-on time. Turn-on time is
denoted by the symbol tON.
Turn off time is defined as the time taken by the output of the MUX50x to fall to 10% initial value after the enable
signal has fallen to 50% initial value. Figure 31 shows the setup used to measure turn-off time. Turn-off time is
denoted by the symbol tOFF.
VDD
VSS
3V
Enable
Drive (VIN)
0V
50%
50%
tON (EN)
VS
Output
0.9 VS
tOFF (EN)
VDD
VSS
A0
S1
VS
A1
S2-S16
A2
A3
MUX506
Output
EN
D
0V
0.1 VS
VIN
GND
300 Ÿ
35 pF
Copyright © 2016, Texas Instruments Incorporated
Figure 31. Turn-On and Turn-Off Time Measurement Setup
20
Submit Documentation Feedback
Product Folder Links: MUX506 MUX507
Copyright © 2016, Texas Instruments Incorporated