Low-Power-Mode Supply Currents (Into VCC) Excluding External Current (1)(2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
ILPM0, 1MHz
Low-power mode 0
(LPM0) current(3)
TEST CONDITIONS
fMCLK = 0 MHz,
fSMCLK = fDCO = 1 MHz,
fACLK = 32768 Hz,
BCSCTL1 = CALBC1_1MHZ,
DCOCTL = CALDCO_1MHZ,
CPUOFF = 1, SCG0 = 0, SCG1 = 0,
OSCOFF = 0
TA
-40°C to 85°C
105°C
-40°C to 85°C
105°C
VCC
2.2 V
3V
MIN TYP
68
88
ILPM0, 100kHz
Low-power mode 0
(LPM0) current(3)
fMCLK = 0 MHz,
fSMCLK = fDCO(0, 0) ≈ 100 kHz,
fACLK = 0 Hz,
RSELx = 0, DCOx = 0,
-40°C to 85°C
105°C
-40°C to 85°C
2.2 V
36
40
CPUOFF = 1, SCG0 = 0, SCG1 = 0,
3V
OSCOFF = 1
105°C
ILPM2
Low-power mode 2
(LPM2) current(4)
fMCLK = fSMCLK = 0 MHz,
fDCO = 1 MHz,
fACLK = 32768 Hz,
BCSCTL1 = CALBC1_1MHZ,
DCOCTL = CALDCO_1MHZ,
CPUOFF = 1, SCG0 = 0, SCG1 = 1,
-40°C to 85°C
105°C
-40°C to 85°C
105°C
2.2 V
3V
20
23
OSCOFF = 0
-40°C to 25°C
0.7
ILPM3, LFXT1
Low-power mode 3
(LPM3) current(4)
fDCO = fMCLK = fSMCLK = 0 MHz,
fACLK = 32768 Hz,
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
OSCOFF = 0
85°C
105°C
-40°C to 25°C
85°C
2.2 V
3V
0.85
105°C
-40°C to 25°C
0.25
ILPM3, VLO
Low-power mode 3
current, (LPM3)(4)
fDCO = fMCLK = fSMCLK = 0 MHz,
fACLK from internal LF oscillator
(VLO),
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
OSCOFF = 0
85°C
105°C
-40°C to 25°C
85°C
2.2 V
3V
0.35
105°C
-40°C
25°C
2.2 V
85°C
1.7
ILPM4
Low-power mode 4
(LPM4) current(5)
fDCO = fMCLK = fSMCLK = 0 MHz,
fACLK = 0 Hz,
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
105°C
-40°C
OSCOFF = 1
25°C
3V
85°C
1.9
105°C
MAX
84
90
110
UNIT
µA
115
45
50
50 µA
54
28
32
32 µA
37
1
3.3
10
µA
1.2
3.8
12
0.8
2.9
9
µA
1
3.5
11
0.5
0.5
2.7
8.6
µA
0.5
0.5
3
9
(1) All inputs are tied to 0 V or VCC. Outputs do not source or sink any current.
(2) The currents are characterized with a Micro Crystal CC4V-T1A SMD crystal with a load capacitance of 9 pF. The internal and external
load capacitance is chosen to closely match the required 9 pF.
(3) Current for brownout and WDT clocked by SMCLK included.
(4) Current for brownout and WDT clocked by ACLK included.
(5) Current for brownout included.
20