English
Language : 

BQ27425-G2_14 Datasheet, PDF (20/35 Pages) Texas Instruments – System-Side Impedance Track™ Fuel Gauge With Integrated Sense Resistor
bq27425-G2
SLUSB23A – OCTOBER 2012 – REVISED FEBRUARY 2013
www.ti.com
The Operation Configuration (Op Config) Register
Gauge operation is configured via the Operation Configuration (Op Config) data NVM register, as indicated in
Table 8. This register is programmed/read via the methods described in Section Accessing the Data NVM.
bit7
High Byte SMOOTHEN
Default =
1
Low Byte
Default =
RSVD1
1
Table 8. Op Config Register Definition
bit6
RSVD0
0
RSVD1
1
bit5
BIE
0
SLEEP
1
bit4
bit3
BI_PU_EN
RSVD1
0
1
0x89
RMFCC
RSVD1
1
1
0xF8
bit2
RSVD0
0
BATLOWEN
0
bit1
RSVD0
0
GPIOPOL
0
bit0
RSVD1
1
TEMPS
0
SMOOTHEN = Enables the SOC smoothing feature. (See SOC Smoothing Feature.) True when set.
BIE = Battery Insertion Enable. If set, the battery insertion is detection via BIN pin input. If cleared, the detection relies
on the host to issue BAT_INSERT subcommand to indicate battery presence in the system.
BI_PU_EN = Enables internal weak pull-up on BIN pin. True when set. If false, an external pull-up resistor is expected.
SLEEP = The fuel gauge can enter sleep, if operating conditions allow. True when set.
RMFCC = RM is updated with the value from FCC on valid charge termination. True when set.
BATLOWEN = If set, the BAT_LOW function for GPOUT pin is selected. If cleared, the SOC_INT function is selected for
GPOUT.
GPIO_POL = GPOUT pin is active-high if set or active-low if cleared.
TEMPS = Selects the temperature source. Enables the host to write Temperature( ) if set. If cleared, the internal
temperature sensor is used for Temperature( ).
RSVD0 = Reserved. Default is 0. (Set to 0 for proper operation)
RSVD1 = Reserved. Default is 1. (Set to 1 for proper operation)
20
Submit Documentation Feedback
Product Folder Links: bq27425-G2
Copyright © 2012–2013, Texas Instruments Incorporated