English
Language : 

TLE2425CLP Datasheet, PDF (2/22 Pages) Texas Instruments – PRECISION VIRTUAL GROUND
TLE2425
PRECISION VIRTUAL GROUND
ą
SLOS065D − MARCH 1991 − REVISED APRIL 2002
D, OR JG PACKAGE
(TOP VIEW)
OUT 1
COMMON 2
IN 3
NC 4
8 NC
7 NC
6 NC
5 NC
ą
LP PACKAGE
(TOP VIEW)
IN
COMMON
OUT
NC − No internal connection
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Continuous input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 V
Output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±80 mA
Duration of short-circuit current at (or below) 25°C (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . unlimited
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: C-suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
I-suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
M-suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D package . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG or LP package . . . . . . . . . . . . . . 300°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum dissipation
rating is not exceeded.
PACKAGE
D
JG
LP
TA ≤ 25°C
POWER RATING
725 mV
1050 mV
775 mV
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25°C
5.8 mW/°C
TA = 70°C
POWER RATING
464 mW
8.4 mW/°C
672 mW
6.2 mW/°C
496 mW
TA = 85°C
POWER RATING
377 mW
546 mW
403 mW
TA = 125°C
POWER RATING
145 mW
210 mW
155 mW
recommended operating conditions
Input voltage, VI
Operating free-air temperature, TA
C-SUFFIX
MIN MAX
4
40
0
70
I-SUFFIX
MIN MAX
4
40
−40 85
M-SUFFIX
MIN MAX
4
40
−55 125
UNIT
V
°C
2
• WWW.TI.COM
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443