English
Language : 

OPA365-EP Datasheet, PDF (2/19 Pages) Texas Instruments – 50-MHz Low-Distortion High-CMRR Rail-to-Rail I/O, Single-Supply Operational Amplifier
OPA365-EP
SLOS735 – AUGUST 2011
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
TA
–55°C to 125°C
ORDERING INFORMATION(1)
PACKAGE
ORDERABLE PART NUMBER
SOT23 – DBV
OPA365AMDBVTEP
TOP-SIDE MARKING
OUNM
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS(1)
VCC Supply voltage
VI
Signal input terminals, voltage(2)
II
Signal input terminals, current(2)
tOSC Output short-circuit duration(3)(4)
TOP Operating temperature
Tstg Storage temperature
TJ
Junction temperature
ESD Electrostatic discharge rating
Human Body Model
Charged Device Model
Machine Model
5.5 V
(V−) − 0.5V to (V+) + 0.5 V
±10 mA
Continuous
−55°C to 125°C
−65°C to 150°C
150°C
4000V
1000V
200V
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Input terminals are diode-clamped to the power-supply rails. Input signals that can swing more than 0.5V beyond the supply rails should
be current limited to 10mA or less.
(3) Short-circuit to ground, one amplifier per package
(4) Continuous output current greater than 20 mA for extended periods may affect product reliability.
2
Submit Documentation Feedback
Product Folder Link(s): OPA365-EP
Copyright © 2011, Texas Instruments Incorporated