English
Language : 

OPA172IDR Datasheet, PDF (2/29 Pages) Texas Instruments – 36-V Single-Supply 10-MHz Rail-to-Rail Output Operational Amplifiers
OPA172
OPA2172
OPA4172
SBOS618 – DECEMBER 2013
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
PACKAGE/ORDERING INFORMATION(1)
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or visit the
device product folder at www.ti.com.
ABSOLUTE MAXIMUM RATINGS(1)
Over operating free-air temperature range, unless otherwise noted.
Supply voltage
Signal input
terminals
Voltage (2)
Current
Output short circuit(3)
Operating temperature
Storage temperature
Junction temperature
Electrostatic
Human body model (HBM)
discharge (ESD)
ratings:
Charged device model (CDM)
Common-mode
Differential
VALUE
±20 (+40 single supply)
(V–) – 0.5 to (V+) + 0.5
±0.5
±10
Continuous
–55 to +150
–65 to +150
+150
4
1
UNIT
V
V
V
mA
°C
°C
°C
kV
kV
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
(2) Transient conditions that exceed these voltage ratings should be current limited to 10 mA or less.
(3) Short-circuit to ground, one amplifier per package.
2
Submit Documentation Feedback
Copyright © 2013, Texas Instruments Incorporated
Product Folder Links: OPA172 OPA2172 OPA4172