OPA121 Datasheet, PDF (2/15 Pages) Burr-Brown (TI) – Low Cost Precision Difet OPERATIONAL AMPLIFIER
SPECIFICATIONS
ELECTRICAL
At VCC = ±15VDC and TA = +25°C unless otherwise noted. Pin 8 connected to ground.
OPA121KM
PARAMETER
CONDITIONS
MIN
TYP
INPUT
NOISE
Voltage, fO = 10Hz
(1)
fO = 100Hz
(1)
fO = 1kHz
(1)
fO = 10kHz
(1)
fB = 10Hz to 10kHz
(1)
fB = 0.1Hz to 10 Hz
(1)
Current, fB = 0.1Hz to 10Hz
(1)
fO = 0.1Hz thru 20kHz
(1)
OFFSET VOLTAGE(2)
Input Offset Voltage
Average Drift
Supply Rejection
VCM = 0VDC
TA = TMIN to TMAX
86
BIAS CURRENT(2)
Input Bias Current
VCM = 0VDC
Device Operating
OFFSET CURRENT(2)
Input Offset Current
VCM = 0VDC
Device Operating
IMPEDANCE
Differential
Common-Mode
VOLTAGE RANGE
Common-Mode Input Range
±10
Common-Mode Rejection
VIN = ±10VDC
86
OPEN-LOOP GAIN, DC
Open-Loop Voltage Gain
RL ≥ 2kΩ
110
FREQUENCY RESPONSE
Unity Gain, Small Signal
Full Power Response
Slew Rate
Settling Time, 0.1%
0.01%
Overload Recovery,
50% Overdrive(3)
20Vp-p, RL = 2kΩ
VO = ±10V, RL = 2kΩ
Gain = –1, RL = 2kΩ
10V Step
Gain = –1
RATED OUTPUT
Voltage Output
Current Output
Output Resistance
RL = 2kΩ
±11
VO = ±10VDC
±5.5
DC, Open Loop
Load Capacitance Stability
Gain = +1
Short Circuit Current
10
POWER SUPPLY
Rated Voltage
Voltage Range,
Derated Performance
Current, Quiescent
±5
IO = 0mADC
TEMPERATURE RANGE
Specification
Ambient Temperature
0
Operating
Ambient Temperature
–40
Storage
Ambient Temperature
–65
θ Junction-Ambient
40
15
8
6
0.7
1.6
15
0.8
±0.5
±3
104
±6
±1
±0.7
1013 || 1
1014 || 3
±11
104
120
2
32
2
6
10
5
±12
±10
100
1000
40
±15
2.5
200
MAX
±2
±10
±50
±5
±4
±18
4
+70
+85
+150
OPA121KP, KU
MIN
TYP
MAX
UNITS
50
nV/√Hz
18
nV/√Hz
10
nV/√Hz
7
nV/√Hz
0.8
µVrms
2
µVp-p
21
fA, p-p
1.1
fA/√Hz
±0.5
±3
mV
±3
±10
µV/°C
86
104
dB
±6
±50
µV/V
±1
±10
pA
±0.7
±8
pA
1013 || 1
1014 || 3
Ω || pF
Ω || pF
±10
±11
V
82
100
dB
106
114
dB
2
MHz
32
kHz
2
V/µs
6
µs
10
µs
5
µs
±11
±12
V
±5.5
±10
mA
100
Ω
1000
pF
10
40
mA
±15
VDC
±5
±18
VDC
2.5
4.5
mA
0
+70
°C
–25
+85
°C
–55
+125
°C
150(4)
°C/W
NOTES: (1) Sample tested. (2) Offset voltage, offset current, and bias current are specified with the units fully warmed up. (3) Overload recovery is defined as
the time required for the output to return from saturation to linear operation following the removal of a 50% input overdrive. (4) 100°C/W for KU grade.
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.
®
OPA121