English
Language : 

LM747QML_16 Datasheet, PDF (2/10 Pages) Texas Instruments – LM747QML Dual Operational Amplifier
LM747QML
SNOSAR6A – DECEMBER 2010 – REVISED MARCH 2013
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings(1)
Supply voltage
Power Dissipation(2)
Differential Input Voltage
Input Voltage(3)
Output Short-Circuit Duration
Maximum Junction Temperature (TJmax)
Operating Temperature Range
Storage Temperature Range
Lead Temperature (Soldering, 10 seconds)
±22V
800mW
±30V
±15V
Indefinite
150°C
−55°C ≤ TA ≤ +125°C
−65°C ≤ TA ≤ +150°C
+300°C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the
Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may
degrade when the device is not operated under the listed test conditions.
(2) The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature),
θJA (package junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any
temperature is PDmax = (TJmax - TA)/θJA or the number given in the Absolute Maximum Ratings, whichever is lower.
(3) For supply voltages less than ±15V, the absolute maximum input voltage is equal to the supply voltage.
Quality Conformance Inspection
Subgroup
1
2
3
4
5
6
7
8A
8B
9
10
11
12
13
14
Mil-Std-883, Method 5005 - Group A
Description
Static tests at
Static tests at
Static tests at
Dynamic tests at
Dynamic tests at
Dynamic tests at
Functional tests at
Functional tests at
Functional tests at
Switching tests at
Switching tests at
Switching tests at
Settling time at
Settling time at
Settling time at
Temp (°C)
+25
+125
-55
+25
+125
-55
+25
+125
-55
+25
+125
-55
+25
+125
-55
2
Submit Documentation Feedback
Product Folder Links: LM747QML
Copyright © 2010–2013, Texas Instruments Incorporated