English
Language : 

CDC9171 Datasheet, PDF (2/5 Pages) Texas Instruments – DVD SYSTEM CLOCK SYNTHESIZER
CDC9171
DVD SYSTEM CLOCK SYNTHESIZER
SCAS558B – DECEMBER 1995 – REVISED OCTOBER 1996
functional block diagram
23
TEST
1X1
1X2
(18.432 MHz)
2
3
ÁÁÁÁÁÁOSCÁÁÁ
ÁÁÁÁÁÁÁÁ2ÁÁÁÁ7P-MLLHÁÁÁÁz ÁÁÁÁ
24 FCLK1
(18.432 MHz)
22 FCLK2
(27 MHz)
17 FCLK3
(27 MHz)
6
PWRDN
ÁÁÁÁÁÁÁÁ33.ÁÁÁÁ8P6L8L-ÁÁÁÁMHzÁÁÁÁ
13 FCLK4
(33.868 MHz)
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6.5 V
Voltage range applied to any output in the high state or power-off state, VO) . . . . . . . . –0.5 V to VCC + 0.5 V
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±35 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Output clamp current, IOK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.65 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
For more information, refer to the Package Thermal Considerations application note in the ABT Advanced BiCMOS Technology Data
Book, literature number SCBD002.
2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265