English
Language : 

PGA900 Datasheet, PDF (19/137 Pages) Texas Instruments – PGA900 Programmable Resistive Sensing Conditioner with Digital and Analog Outputs
www.ti.com
Diagnostics (continued)
over operating free-air temperature range at VDD = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
HARNESS_
FAULT2
Open wire leakage
current 2 - open
GND with pull-
down on VOUT1
6.26 M0
over operating free-air temperature range at VDD = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
M0 frequency control bit = 0b00
M0 core frequency (including OTP
and RAM)
M0 frequency control bit = 0b01
M0 frequency control bit = 0b10
M0 frequency control bit = 0b11
PGA900
SLDS209A – JANUARY 2015 – REVISED MAY 2015
MIN TYP MAX UNIT
20
µA
MIN
TYP
MAX UNIT
0.5
1
MHz
2
4
Copyright © 2015, Texas Instruments Incorporated
Product Folder Links: PGA900
Submit Documentation Feedback
19