English
Language : 

BQ27425-G2_15 Datasheet, PDF (18/39 Pages) Texas Instruments – Fuel Gauge With Integrated Sense Resistor
bq27425-G2
SLUSB23B – OCTOBER 2012 – REVISED JUNE 2015
www.ti.com
8.5.1.1.7 BAT_REMOVE: 0X000D
This subcommand forces the Flags() [BAT_DET] bit to clear when the battery insertion detection is disabled
through Op Config [BIE] = 0. In this case, the gauge does not detect battery removal from the BIN pin logic
state, but relies on the BAT_REMOVE host subcommand to indicate battery removal from the system.
8.5.1.1.8 SET_HIBERNATE: 0x0011
Instructs the fuel gauge to force the CONTROL_STATUS [HIBERNATE] bit to 1. If the necessary conditions are
met, this enables the gauge to enter the HIBERNATE power mode after the transition to SLEEP power state is
detected. The [HIBERNATE] bit is automatically cleared upon exiting from HIBERNATE mode.
8.5.1.1.9 CLEAR_HIBERNATE: 0x0012
Instructs the fuel gauge to force the CONTROL_STATUS [HIBERNATE] bit to 0. This prevents the gauge from
entering the HIBERNATE power mode after the transition to SLEEP power state is detected. It can also be used
to force the gauge out of HIBERNATE mode.
8.5.1.1.10 SET_CFGUPDATE: 0x0013
Instructs the fuel gauge to set the Flags() [CFGUPMODE] bit to 1 and enter CONFIG UPDATE mode. This
command is only available when the fuel gauge is UNSEALED.
NOTE
A SOFT_RESET subcommand is typically used to exit CONFIG UPDATE mode to resume
normal gauging.
8.5.1.1.11 SEALED: 0x0020
Instructs the fuel gauge to transition from UNSEALED state to SEALED state. The fuel gauge should always be
set to SEALED state for use in end equipment.
8.5.1.1.12 RESET: 0x0041
This command instructs the fuel gauge to perform a full device reset and reinitialize RAM data to the default
values from ROM. The gauge sets the Flags() [ITPOR] bit and enters the INITIALIZE mode. See Figure 6. This
command is only available when the fuel gauge is UNSEALED.
8.5.1.1.13 SOFT_RESET: 0x0042
This command instructs the fuel gauge to perform a partial (soft) reset from any mode with an OCV
measurement. The Flags() [ITPOR, CFGUPMODE] bits are cleared and a resimulation occurs to update
StateOfCharge( ). See Figure 6. This command is only available when the fuel gauge is UNSEALED.
18
Submit Documentation Feedback
Product Folder Links: bq27425-G2
Copyright © 2012–2015, Texas Instruments Incorporated