8.5.1.1 Control(): 0x00 and 0x01
Issuing a Control( ) command requires a subsequent 2-byte subcommand. These additional bytes specify the
particular control function desired. The Control( ) command allows the system to control specific features of the
bq27425 during normal operation and additional features when the bq27425 is in different access modes, as
described in Table 4.
CNTL FUNCTION
CONTROL_STATUS
DEVICE_TYPE
FW_VERSION
PREV_MACWRITE
CHEM_ID
BAT_INSERT
BAT_REMOVE
SET_HIBERNATE
CLEAR_HIBERNATE
SET_CFGUPDATE
SEALED
RESET
SOFT_RESET
CNTL DATA
0x0000
0x0001
0x0002
0x0007
0x0008
0x000c
0x000d
0x0011
0x0012
0x0013
0x0020
0x0041
0x0042
Table 4. Control( ) Subcommands
SEALED ACCESS
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
DESCRIPTION
Reports the status of device.
Reports the device type (0x0425).
Reports the firmware version of the device.
Returns previous MAC command code.
Reports the chemical identifier of the Impedance Track™ configuration
Forces the Flags() [BAT_DET] bit set when the Op Config [BIE] bit is 0.
Forces the Flags() [BAT_DET] bit clear when the Op Config [BIE] bit is
0.
Forces CONTROL_STATUS [HIBERNATE] to 1.
Forces CONTROL_STATUS [HIBERNATE] to 0.
Forces Flags( ) [CFGUPMODE] to 1 and gauge enters CONFIG
UPDATE mode.
Places the bq27425 in SEALED access mode.
Performs a full device reset.
Gauge exits CONFIG UPDATE mode.