BQ2060A_15 Datasheet, PDF (18/61 Pages) Texas Instruments – SBS v1.1-Compliant Gas Gauge IC
bq2060A
SLUS500D – OCTOBER 2001 – REVISED OCTOBER 2011
Table 7. 5-LED Display Mode
Condition Relative or Absolute
StateOfCharge()
EDV0 = 1
<20%
≤20%, <40%
≤40%, <60%
≤60%, <80%
≤80%
LED1
OFF
ON
ON
ON
ON
ON
5-LED Display Option
LED2
LED3
LED4
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
LED5
OFF
OFF
OFF
OFF
OFF
ON
www.ti.com
Table 8. 4-LED Display Mode
Condition Relative or Absolute
StateOfCharge()
EDV0 = 1
<25%
≤25%, <50%
≤50%, <75%
≤75%
LED1
OFF
ON
ON
ON
ON
4-LED Display Option
LED2
LED3
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
LED4
OFF
OFF
OFF
OFF
ON
The CVUV status flag is set if any VCELL voltage < Cell Undervoltage threshold. When CVUV = 1, the DFC pin
is pulled low unless DISCHARGING bit in BatteryStatus() is clear (not set).
Cell Undervoltage and Cell Overvoltage limits may be programmed in the upper and lower nibbles of EE 0x4a.
Safety Overtemperature threshold may be programmed in EE 0x09, and Miscellaneous Options is programmed
in EE 0x08.
Low-Power Storage Mode
The bq2060A enters low-power mode 5 s to 8 s after receiving the Enable Low-Power command. In this mode,
the bq2060A consumes less than 10 µA. A rising edge on SMBC, SMBD, or HDQ16 restores the bq2060A to the
full operating mode. The bq2060A does not perform any gas gauge functions during low-power storage mode.
Device Reset
The bq2060A can be reset when power is applied or by commands over the HDQ16 or SMBus. On reset, the
bq2060A initializes its internal registers with the information contained in the configuration EEPROM. The
following command sequence initiates a full bq2060A reset:
Write 0xff5a to address 0x4f
Write 0x0000 to address 0x7d
Write 0x0080 to address 0x7d
A partial reset of the bq2060A occurs if step 1 is omitted and all check-byte values previously loaded into RAM
are still correct. All initial RAM values are read from EEPROM for both full and partial resets. A full reset
initializes MaxError = 100%, sets RELEARN_FLAG (bit 7) = 1 in Battery Mode, and initializes RM from EE
0x2c–2d (should be zero for rechargeable batteries). A partial reset leaves MaxError, RELEARN_FLAG, and RM
unchanged. The bq2060A delays reading the EEPROM for 700 ms after all resets to allow settling time for VCC.
COMMUNICATION
The bq2060A includes two types of communication ports: SMBus and HDQ16. The SMBus interface is a 2-wire
bidirectional protocol using the SMBC (clock) and SMBD (data) pins. The HDQ16 interface is a 1-wire
bidirectional protocol using the HDQ16 pin. All three communication lines are isolated from VCC and may be
pulled up higher than VCC. Also, the bq2060A does not pull these lines low if VCC to the part is zero. HDQ16
should be pulled down with a 100-kΩ resistor if not used.
The communication ports allow a host controller, an SMBus compatible device, or other processor to access the
memory registers of the bq2060A. In this way, a system can efficiently monitor and manage the battery.
18
Submit Documentation Feedback
Product Folder Link(s): bq2060A
Copyright © 2001–2011, Texas Instruments Incorporated