English
Language : 

TLC2810Z Datasheet, PDF (16/23 Pages) Texas Instruments – LinCMOSE PRECISION DUAL OPERATIONAL AMPLIFIERS
TLC2810Z, TLC2810Y
LinCMOS™ PRECISION
DUAL OPERATIONAL AMPLIFIERS
SLOS120A – AUGUST 1993 – REVISED AUGUST 1994
PARAMETER MEASUREMENT INFORMATION
single-supply versus split-supply test circuits
Because the TLC2810Z is optimized for single-supply operation, circuit configurations used for the various tests
often present some inconvenience since the input signal, in many cases, must be offset from ground. This
inconvenience can be avoided by testing the device with split supplies and the output load tied to the negative
rail. A comparison of single-supply and split-supply test circuits is shown below. The use of either circuit gives
the same result.
VDD
–
VI
+
CL
VO
RL
VDD +
–
VI
+
CL
VO
RL
1/2 VDD
(a) SINGLE SUPPLY
VDD –
(b) SPLIT SUPPLY
Figure 26. Unity-Gain Amplifier
2 kΩ
2 kΩ
VDD
20 Ω
–
+
VO
20 Ω
20 Ω
VDD +
–
+
20 Ω
(a) SINGLE SUPPLY
Figure 27. Noise-Test Circuit
10 kΩ
VDD –
(b) SPLIT SUPPLY
10 kΩ
VI
1/2 VDD
100 Ω
VDD
–
+
VO
CL
100 Ω
VI
VDD +
–
+
(a) SINGLE SUPPLY
Figure 28. Gain-of-100 Inverting Amplifier
VDD –
(b) SPLIT SUPPLY
VO
VO
CL
16
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265