English
Language : 

BQ2011_15 Datasheet, PDF (15/26 Pages) Texas Instruments – Gas Gauge IC for High Discharge Rates
bq2011
Absolute Maximum Ratings
Symbol
Parameter
VCC
Relative to VSS
All other pins Relative to VSS
Minimum
-0.3
-0.3
Maximum
+7.0
+7.0
VSR
Relative to VSS
-0.3
+7.0
TOPR
0
+70
Operating temperature
Unit
Notes
V
V
Minimum 100Ω series resistor
V
should be used to protect SR in case
of a shorted battery (see the bq2011
application note for details).
°C Commercial
Note:
Permanent device damage may occur if Absolute Maximum Ratings are exceeded. Functional opera-
tion should be limited to the Recommended DC Operating Conditions detailed in this data sheet. Expo-
sure to conditions beyond the operational limits for extended periods of time may affect device reliability.
DC Voltage Thresholds (TA = TOPR; V = 3.0 to 6.5V)
Symbol
Parameter
Minimum Typical Maximum Unit
Notes
VEDV
End-of-discharge warning
0.87
0.90
0.93
V SB
VSR1
Discharge compensation threshold
20
50
75
mV SR (see note)
VSR2
Discharge compensation threshold
70
100
125
mV SR (see note)
VSR3
Discharge compensation threshold
120
150
175
mV SR (see note)
VSR4
Discharge compensation threshold
220
253
275
mV SR (see note)
VSRQ
Valid charge
-
-
-400
µV VSR + VOS
VSRD
Valid discharge
500
-
-
µV VSR + VOS
VMCV
Maximum single-cell voltage
1.95
2.0
2.05
V SB
VBR
Battery removed/replaced
-
0.1
0.25
V SB
Note:
For proper operation of the threshold detection circuit, VCC must be at least 1.5V greater than the volt-
age being measured.
15