English
Language : 

AMC1200BDUBR Datasheet, PDF (14/24 Pages) Texas Instruments – Fully-Differential Isolation Amplifier
AMC1200
AMC1200B
SBAS542B – APRIL 2011 – REVISED AUGUST 2012
www.ti.com
VOLTAGE MEASUREMENT
The AMC1200 and AMC1200B can also be used for isolated voltage measurement applications, as shown in a
simplified way in Figure 34. In such applications, usually a resistor divider (R1 and R2 in Figure 34) is used to
match the relatively small input voltage range of the AMC device. R2 and the input resistance RIN of the
AMC1200 also create a resistance divider that results in additional gain error. With the assumption that R1 and
RIN have a considerably higher value than R2, the resulting total gain error can be estimated using Equation 1:
GERRTOT
=
GERR
+
R2
RIN
Where GERR = the gain error of AMC device.
(1)
L1
R1
R2
RIN
L2
Figure 34. Voltage Measurement Application
14
Submit Documentation Feedback
Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Links: AMC1200 AMC1200B