English
Language : 

TLC2272-Q1 Datasheet, PDF (10/39 Pages) Texas Instruments – ADVANCED LinCMOS™ RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
TLC2272-Q1 , TLC2272A-Q1
TLC2274-Q1, TLC2274A-Q1
SGLS007E – FEBRUARY 2003 – REVISED JANUARY 2012
www.ti.com
TLC2274Q ELECTRICAL CHARACTERISTICS
at specified free-air temperature, VDD± = ±5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TA (1)
MIN
VIO Input offset voltage
25°C
Full range
αVIO
Temperature
coefficient of input
offset voltage
Input offset voltage
long-term drift(2)
VIC = 0 V,
RS = 50 Ω
VO = 0 V
25°C to 125°C
25°C
IIO
Input offset current
25°C
Full range
IIB
Input bias current
25°C
Full range
VICR
Common-mode input
voltage range
RS = 50 Ω
|VIO| ≤ 5
mV
IO = −20 μA
VOM+
Maximum positive
peak output voltage
IO = −200 μA
IO = −1 mA
VIC = 0 V,
VOM-
Maximum negative
peak output voltage
VIC = 0 V,
VIC = 0 V,
IO = 50 μA
IO = 500
μA
IO = 5 mA
AVD
rid
ri
ci
zo
CMR
R
kSVR
Large-signal
differential voltage
amplification
Differential input
resistance
VO = ±4 V,
RL = 10 kΩ
RL = 1 MΩ
Common-mode input
resistance
Common-mode input f = 10 kHz,
capacitance
N package
Closed-loop output f = 1 MHz,
impedance
AV = 10
Common-mode
rejection ratio
Supply voltage
rejection ratio
(ΔVDD/ΔVIO)
VIC = -5 V to
2.7 V,
VO = 0 V,
RS = 50 Ω
VDD = ±2.2 V to ±8 V,
VIC = 0V,
No load
IDD Supply current
VO = 0 V,
No load
25°C
Full range
25°C
25°C
Full range
25°C
Full range
25°C
25°C
Full range
25°C
Full range
25°C
Full range
25°C
25°C
25°C
25°C
25°C
25°C
Full range
25°C
Full range
25°C
Full range
−5 to 4
−5 to
3.5
4.85
4.85
4.25
4.25
−4.85
−4.85
−3.5
−3.5
20
20
75
75
80
80
TLC2274Q
TYP
300
2
0.002
0.5
1
−5.3 to
4.2
4.99
4.93
4.65
−4.99
−4.91
−4.1
50
300
1012
1012
8
130
80
95
4.4
MAX
2500
3000
TLC2274AQ
MIN
TYP
300
UNIT
MAX
950
μV
1500
2
μV/°C
60
800
60
800
−5 to 4
−5 to 3.5
4.85
4.85
4.25
4.25
−4.85
−4.85
−3.5
−3.5
20
20
0.002
0.5
1
−5.3 to
4.2
4.99
4.93
4.65
−4.99
−4.91
−4.1
50
300
1012
μV/m
o
60
pA
800
60
pA
800
V
V
V
V/mV
Ω
1012
Ω
8
pF
130
Ω
75
80
dB
75
80
95
dB
80
6
4.4
6
mA
6
6
(1) Full range is −40°C to 125°C for Q level part.
(2) Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to
TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
10
Submit Documentation Feedback
Copyright © 2003–2012, Texas Instruments Incorporated
Product Folder Link(s): TLC2272-Q1 TLC2272A-Q1 TLC2274-Q1 TLC2274A-Q1