English
Language : 

BQ20Z75_08 Datasheet, PDF (9/20 Pages) Texas Instruments – SBS 1.1-COMPLIANT GAS GAUGE AND PROTECTION-ENABLED IC WITH IMPEDANCE TRACK
bq20z75
www.ti.com............................................................................................................................................................... SLUS723C – JULY 2007 – REVISED JULY 2008
Electrical Characteristics (continued)
over operating free-air temperature range (unless otherwise noted), TA = –40°C to 85°C, VREG25 = 2.41 V to 2.59 V, VBAT =
14V, CREG25 = 1µF, CREG33 = 2.2µF; typical values at TA = 25°C (unless otherwise noted)
PARAMETER
f(EIO)
Frequency error (12)(13)
t(SXO)
Start-up time(14)
LOW FREQUENCY OSCILLATOR
f(LOSC) Operating frequency
f(LEIO)
Frequency error(13)(15)
t(LSXO)
Start-up time(14)
TEST CONDITIONS
TA = 20°C to 70°C
TA = 20°C to 70°C
MIN
–3%
–2%
TYP
0.25%
0.25%
2.5
MAX
3%
2%
5
UNIT
ms
–2.5%
–1.5%
32.768
0.25%
0.25%
kHz
2.5%
1.5%
500 µs
(12) The frequency error is measured from 4.194 MHz.
(13) The frequency drift is included and measured from the trimmed frequency at VREG25 = 2.5V, TA = 25°C
(14) The startup time is defined as the time it takes for the oscillator output frequency to be ±3%
(15) The frequency error is measured from 32.768 kHz.
Data Flash Characteristics Over Recommended Operating Temperature and Supply Voltage
Typical Values at TA = 25°C and VREG25= 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
Data retention
10
Years
Flash programming write-cycles
t(ROWPROG) Row programming time
t(MASSERASE) Mass-erase time
t(PAGEERASE) Page-erase time
I(DDPROG) Flash-write supply current
I(DDERASE) Flash-erase supply current
RAM BACKUP
See (1)
20k
Cycles
2
ms
200
ms
20
ms
5
10 mA
5
10 mA
I(RB)
V(RB)
RB data-retention input current
RB data-retention input voltage(1)
V(RBI) > V(RBI)MIN , VREG25 < VIT–,
TA = 85°C
V(RBI) > V(RBI)MIN , VREG25 < VIT–,
TA = 25°C
1000 2500
nA
90 220
1.7
V
(1) Assured by design. Not production tested.
SMBus Timing Characteristics
TA = –40°C to 85°C Typical Values at TA = 25°C and V(REG25) = 2.5 V (Unless Otherwise Noted)
PARAMETER
TEST CONDITIONS
MIN
fSMB
SMBus operating frequency
fMAS
SMBus master clock frequency
Slave mode, SMBC 50% duty cycle
10
Master mode, No clock low slave
extend
t(BUF)
Bus free time between start and stop
4.7
(see Figure 1)
t(HD:STA) Hold time after (repeated) start (see Figure 1)
4.0
t(SU:STA) Repeated start setup time (see Figure 1)
4.7
t(SU:STO) Stop setup time (see Figure 1)
4.0
t(HD:DAT)
Data hold time (see Figure 1)
Receive mode
0
Transmit mode
300
t(SU:DAT) Data setup time (see Figure 1)
250
TYP MAX
100
51.2
UNIT
kHz
kHz
µs
µs
µs
µs
ns
ns
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): bq20z75
Submit Documentation Feedback
9