English
Language : 

TL071_10 Datasheet, PDF (8/40 Pages) Texas Instruments – LOW-NOISE JFET-INPUT OPERATIONAL AMPLIFIERS
TL071, TL071A, TL071B, TL072
TL072A, TL072B, TL074, TL074A, TL074B
LOW-NOISE JFET-INPUT OPERATIONAL AMPLIFIERS
SLOS080J − SEPTEMBER 1978 − REVISED MARCH 2005
electrical characteristics, VCC± = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS†
TA‡
TL071M
TL072M
TL074M
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
VO = 0,
25°C
RS = 50 Ω Full range
3
6
9
3
9
mV
15
αVIO
Temperature coefficient of
input offset voltage
VO = 0,
RS = 50 Ω Full range
18
18
μV/°C
IIO
Input offset current
VO = 0
25°C
Full range
5 100
20
5 100 pA
20 nA
IIB
Input bias current‡
VO = 0
25°C
65 200
50
65 200 pA
50 nA
VICR
Common-mode input
voltage range
−12
−12
25°C
±11
to
±11
to
V
15
15
VOM
Maximum peak output
voltage swing
RL = 10 kΩ
RL ≥ 10 kΩ
RL ≥ 2 kΩ
25°C
Full range
±12 ±13.5
±12
±10
Large-signal differential
25°C
35 200
AVD
voltage amplification
VO = ±10 V, RL ≥ 2 kΩ
15
±12 ±13.5
±12
±10
35 200
15
V
V/mV
B1
ri
CMRR
kSVR
ICC
Unity-gain bandwidth
Input resistance
Common-mode rejection
ratio
Supply-voltage rejection
ratio (ΔVCC±/ΔVIO)
Supply current (each
amplifier)
TA = 25°C
TA = 25°C
VIC = VICRmin,
VO = 0,
RS = 50 Ω
VCC = ±9 V to ±15 V,
VO = 0,
RS = 50 Ω
VO = 0,
No load
25°C
25°C
25°C
3
1012
80 86
80 86
1.4 2.5
3
1012
80 86
MHz
Ω
dB
80 86
dB
1.4 2.5 mA
VO1/VO2 Crosstalk attenuation
AVD = 100
25°C
120
120
dB
† Input bias currents of an FET-input operational amplifier are normal junction reverse currents, which are temperature sensitive, as shown in
Figure 4. Pulse techniques must be used that will maintain the junction temperature as close to the ambient temperature as possible.
‡ All characteristics are measured under open-loop conditions with zero common-mode voltage, unless otherwise specified. Full range is
TA = −55°C to 125°C.
8
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265