English
Language : 

TL071_10 Datasheet, PDF (7/40 Pages) Texas Instruments – LOW-NOISE JFET-INPUT OPERATIONAL AMPLIFIERS
electrical characteristics, VCC± = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS†
TA‡
TL071C
TL072C
TL074C
TL071AC
TL072AC
TL074AC
TL071BC
TL072BC
TL074BC
TL071I
TL072I
TL074I
UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX
25°C
VIO
Input offset voltage VO = 0,
RS = 50 Ω Full range
3 10
13
3
6
7.5
2
3
5
3
6
mV
8
Temperature
α
VIO
coefficient of input VO = 0,
RS = 50 Ω Full range
18
18
18
18
μV/°C
offset voltage
IIO
Input offset current VO = 0
25°C
Full range
5 100
10
5 100
2
5 100
2
5 100 pA
2 nA
IIB
Input bias current§ VO = 0
25°C
Full range
65 200
7
65 200
7
65 200
7
65 200 pA
20 nA
VICR
VOM
AVD
Common-mode
input voltage range
Maximum peak
output voltage
swing
Large-signal
differential voltage
amplification
RL = 10 kΩ
RL ≥ 10 kΩ
RL ≥ 2 kΩ
VO = ±10 V, RL ≥ 2 kΩ
25°C
25°C
Full range
25°C
Full range
−12
±11
to
15
±12 ±13.5
±12
±10
25 200
15
−12
±11
to
15
±12 ±13.5
±12
±10
50 200
25
−12
±11
to
15
±12 ±13.5
±12
±10
50 200
25
−12
±11
to
15
±12 ±13.5
±12
±10
50 200
25
V
V
V/mV
B1
Unity-gain
bandwidth
25°C
3
3
3
3
MHz
ri
CMRR
kSVR
ICC
Input resistance
Common-mode
rejection ratio
Supply-voltage
rejection ratio
(ΔVCC ± /ΔVIO)
Supply current
(each amplifier)
VIC = VICRmin,
VO = 0,
RS = 50 Ω
VCC = ± 9 V to ±15 V,
VO = 0,
RS = 50 Ω
VO = 0,
No load
25°C
25°C
25°C
25°C
1012
70 100
70 100
1012
75 100
80 100
1012
75 100
80 100
1012
Ω
75 100
dB
80 100
dB
1.4 2.5
1.4 2.5
1.4 2.5
1.4 2.5 mA
VO1/ VO2
Crosstalk
attenuation
AVD = 100
25°C
120
120
120
120
dB
† All characteristics are measured under open-loop conditions with zero common-mode voltage, unless otherwise specified.
‡ Full range is TA = 0°C to 70°C for TL07_C,TL07_AC, TL07_BC and is TA = −40°C to 85°C for TL07_I.
§ Input bias currents of an FET-input operational amplifier are normal junction reverse currents, which are temperature sensitive, as shown in Figure 4. Pulse techniques must be used
that maintain the junction temperature as close to the ambient temperature as possible.