English
Language : 

TC254P Datasheet, PDF (8/16 Pages) Texas Instruments – 336- × 244-pixel ccd image sensor
TC254P
336- × 244-PIXEL CCD IMAGE SENSOR
SOCS060B – JUNE 1997 – REVISED JULY 1998
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage range, VCC: ADB (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to 15 V
Input voltage range, VI: ABG, IAG1, IAG2, SAG, SRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 15 V to 15 V
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 10°C to 45°C
Storage temperature range, TSTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30°C to 85°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to the substrate terminal.
recommended operating conditions
Supply voltage, VCC
Substrate bias voltage
Input voltage, VI
ADB
IAG1, IAG2
SAG
SRG
ABG
ABG
Clock frequency, fclock
IAG1, IAG2
SAG
SRG
Load capacitance
OUT
Plastic package thermal conductivity
Operating free-air temperature, TA
‡ Adjustment is required for optimum performance.
High level
Low level
High level
Low level
High level
Low level
High level
Intermediate level‡
Low level
MIN
11
1.5
–10.5
1.5
–10.5
1.5
–10.5
3.5
–8
NOM
12
0
2
–10
2
–10
2
–10
4
–2.5
–7
6.25
6.25
0.008
–10
MAX
13
2.5
–9.5
2.5
–9.5
2.5
–9.5
4.5
UNIT
V
V
V
–6
12.5
25
MHz
12.5
12.5
6
pF
J/cm•s•°C
45
°C
8