English
Language : 

BQ20Z60-R1 Datasheet, PDF (8/15 Pages) Texas Instruments – SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK™ TECHNOLOGY FOR USE WITH THE bq29330
bq20z60-R1
SLUS991 – DECEMBER 2009
FEATURE SET
www.ti.com
Primary (1st Level) Safety Features
The bq20z60-R1 supports a wide range of battery and system protection features that can easily be configured.
The primary safety features include:
• Cell over/undervoltage protection
• Charge and discharge overcurrent
• Short circuit protection
• Charge and discharge overtemperature with independent alarms and thresholds for each thermistor
• AFE Watchdog
Secondary (2nd Level) Safety Features
The secondary safety features of the bq20z60-R1 can be used to indicate more serious faults via the SAFE pin.
This pin can be used to blow an in-line fuse to permanently disable the battery pack from charging or
discharging. The secondary safety protection features include:
• Safety over voltage
• Safety under voltage
• 2nd level protection IC input
• Safety over current in charge and discharge
• Safety overtemperature in charge and discharge with independent alarms and thresholds for each thermistor
• Charge FET and zero-volt Charge FET fault
• Discharge FET fault
• Cell imbalance detection (active and at rest)
• Open thermistor detection
• AFE communication fault
Charge Control Features
The bq20z60-R1 charge control features include:
• Supports JEITA temperature ranges. Reports charging voltage and charging current according to the
active temperature range.
• Handles more complex charging profiles. Allows for splitting the standard temperature range into 2
sub-ranges and allows for varying the charging current according to the cell voltage.
• Reports the appropriate charging current needed for constant current charging and the appropriate
charging voltage needed for constant voltage charging to a smart charger using SMBus broadcasts.
• Determines the chemical state of charge of each battery cell using Impedance Track™ and can reduce
the charge difference of the battery cells in fully charged state of the battery pack gradually using cell
balancing algorithm during charging. This prevents fully charged cells from overcharging and causing
excessive degradation and also increases the usable pack energy by preventing premature charge
termination
• Supports pre-charging/zero-volt charging
• Supports charge inhibit and charge suspend if battery pack temperature is out of temperature range
• Reports charging fault and also indicate charge status via charge and discharge alarms.
Gas Gauging
The bq20z60-R1 uses the Impedance Track™ Technology to measure and calculate the available charge in
battery cells. The achievable accuracy is better than 1% error over the lifetime of the battery and there is no full
charge discharge learning cycle required.
See Theory and Implementation of Impedance Track Battery Fuel-Gauging Algorithm application note (SLUA364)
for further details.
8
Submit Documentation Feedback
Product Folder Link(s) :bq20z60-R1
Copyright © 2009, Texas Instruments Incorporated