AMC1203
SBAS427 – FEBRUARY 2008
TIMING INFORMATION
MCLK
MDAT
tHIGH
tCLK
tD
tS
tH
Figure 2. Modulator Output Mode Timing
www.ti.com
TIMING CHARACTERISTICS FOR MODULATOR OUTPUT MODE
Over recommended operating free-air temperature range at –40°C to +105°C, VDD1 = +5V, and VDD2 = +5V, unless otherwise noted.
PARAMETER
MIN
TYP
MAX
UNIT
tCLK
tHIGH
tD
tS
tH
MCLK clock period
MCLK clock high time
Data delay after falling edge of MCLK
Data setup time prior to rising edge of MCLK
Data hold time after rising edge of MCLK
83.33
(tCLK/2) – 8
–2
31.5
31.5
100
125
ns
tP/2
(tCLK/2) + 8
ns
0
2
ns
ns
ns