PIN CONFIGURATIONS
Top View
DWP
TERMINAL
NAME
NO.
ERROR
1
DMAG
2
GAIN
3
REFOUT
4
REFIN
5
VOUT
6
IAIN2
7
IAIN1
8
GND2
9
ICOMP2
10
ICOMP1
11
VDD2
12
CCdiag
13
OVER-RANGE
14
VDD1
15
IS2
16
GND1
17
IS1
18
PWM
19
PWM
20
Exposed Thermal Pad
–
PWM 1
PWM 2
ERROR 3
DEMAG 4
GAIN 5
REFOUT 6
REFIN 7
VOUT 8
IAIN2 9
IAIN1 10
Exposed
Thermal Pad
on Underside,
Connect
to GND1
20 IS1
19 GND1
18 IS2
17 VDD1
16 OVER- RANGE
15 CCdiag
14 VDD2
13 ICOMP1
1 2 ICOMP2
11 GND2
Wide- Body SO- 20
PIN ASSIGNMENTS
DESCRIPTION
Error flag: open-drain output, see the Error Conditions section.
Control input, see the Demagnetization section.
Control input for open-loop gain: low = normal, high = –8 dB.
Output for internal 2.5 V reference voltage.
Input for zero reference to differential amplifier.
Output for differential amplifier.
Noninverting input of differential amplifier.
Inverting input of differential amplifier.
Ground connection. Connect to GND1.
Output 2 of compensation coil driver.
Output 1 of compensation coil driver.
Supply voltage. Connect to VDD1.
Control input for wire-break detection: high = enable.
Open-drain output for over-range indication: low = over-range.
Supply voltage.
Probe connection 2.
Ground connection.
Probe connection 1.
PWM output from probe circuit (inverted).
PWM output from probe circuit.
Connect to GND1.