English
Language : 

BQ20Z90_07 Datasheet, PDF (6/27 Pages) Texas Instruments – SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK™ TECHNOLOGY FOR USE WITH THE bq29330
bq20z90
SLUS662A – DECEMBER 2005 – REVISED JUNE 2006
OSCILLATOR (continued)
VCC = 2.4 V to 2.6 V, TA = –40°C to 85°C (unless otherwise noted)
PARAMETER
t(LSXO) Start-up time (5)
TEST CONDITIONS
(5) The start-up time is defined as the time it takes for the oscillator output frequency to be ± 3%.
www.ti.com
MIN TYP MAX UNIT
500 µs
DATA FLASH MEMORY CHARACTERISTICS
VCC = 2.4 V to 2.6 V, TA = –40°C to 85°C (unless otherwise noted)
PARAMETER
tDR
Data retention
Flash programming write-cycles
t(WORDPROG) Word programming time
I(DDdPROG) Flash-write supply current
See (1)
See (1)
See (1)
See (1)
TEST CONDITIONS
(1) Assured by design. Not production tested
MIN
10
20,000
TYP MAX UNIT
Years
Cycles
2 ms
5
10 mA
REGISTER BACKUP
VCC = 2.4 V to 2.6 V, TA = –40°C to 85°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
I(RB) RB data-retention input current
V(RB) RB data-retention voltage(1)
V(RB) > V(RBMIN), VCC < VIT-
V(RB) > V(RBMIN), VCC < VIT-, TA = 0°C
to 50°C
(1) Specified by design. Not production tested.
MIN TYP MAX UNIT
1500 nA
40 160
1.7
V
6
Submit Documentation Feedback