English
Language : 

AMC7832_15 Datasheet, PDF (53/72 Pages) Texas Instruments – AMC7832 12-Bit Analog Monitor and Control Solution with Multi-Channel ADC, Bipolar DACs, Temperature Sensor and GPIO Ports
www.ti.com
AMC7832
SLAS836 – MARCH 2014
Table 51. Register name: Register name: Power-down 0 – Address: 0xB2, Default: 0x00 (READ/WRITE)
REGISTER
NAME
Power
Down 0
ADDRESS
0xB2
BIT NAME
7
PDAC-C1
6
PDAC-C0
5
PDAC-B7
4
PDAC-B6
3
PDAC-A11
2
PDAC-A10
1
PDAC-A9
0
PDAC-A8
DESCRIPTION
DEFAULT
VALUE
After power-on or reset, all bits in the Power-Down Register are
0
cleared to '0', and all the components controlled by this register
are either powered-down or off. The Power-Down Register allows
0
the host to manage the AMC7832 power dissipation. When not
0
required, the ADC, internal reference, reference buffer amplifiers,
and any of the DACs can be put into an inactive low-power mode
0
to reduce current drain from the supply. The bits in the Power-
0
Down Register control this power-down function. Set the
0
respective bit to '1' to activate the corresponding function.
0
0
Table 52. Register name: Register name: Power-down 1 – Address: 0xB3, Default: 0x00 (READ/WRITE)
REGISTER
NAME
Power
Down 1
ADDRESS
0xB3
BIT NAME
7
PREF_OUT1
6
PREF_OUT2
5
PREF
4
PADC
3
PDAC-D5
2
PDAC-D4
1
PDAC-D3
0
PDAC-D2
DESCRIPTION
DEFAULT
VALUE
After power-on or reset, all bits in the Power-Down Register are
0
cleared to '0', and all the components controlled by this register
are either powered-down or off. The Power-Down Register allows
0
The Power-Down Register allows the host to manage the
0
AMC7832 power dissipation. When not required, the ADC,
internal reference, reference buffer amplifiers, and any of the
0
DACs can be put into an inactive low-power mode to reduce
0
current drain from the supply. The bits in the Power-Down
0
Register control this power-down function. Set the respective bit
to '1' to activate the corresponding function.
0
0
8.5.14 ADC Trigger: Address 0xC0
Table 53. Register name: ADC Trigger – Address: 0xC0, Default: 0x00 (WRITE ONLY)
REGISTER
NAME
ADDRESS
ADC Trigger 0xC0
BIT NAME
7:1 Reserved
0
ICONV
DESCRIPTION
Reserved for factory use
Internal ADC conversion bit. Set this bit to ‘1’ to start the ADC
conversion internally. The bit is automatically cleared to ‘0’.
DEFAULT
VALUE
All zeros
0
Copyright © 2014, Texas Instruments Incorporated
Product Folder Links: AMC7832
Submit Documentation Feedback
53